indicating the location of the nearest accessible entrance(s) shall be installed at or near the inaccessible entrance, such that a person with disabilities will not be required to retrace the approach...
Search Results "Approach"
-
4.1.6(1)(h) Entrances
-
1015.2 Clear Ground Space
The clear ground space shall be 36 inches (915 mm) minimum by 48 inches (1220 mm) minimum and shall be positioned for either a forward or parallel approach to the viewing location....
-
Factors to Consider in Planning For & Administering an ADA Facilities Compliance Plan
Second, the size, type, and geographic separateness of your facilities should affect your approach....
-
604.8.2.2 Doors
Toilet compartment doors, including door hardware, shall comply with 404, except that if the approach is to the latch side of the compartment door, clearance between the door side of the...
-
604.8.2.2 Doors
Toilet compartment doors, including door hardware, shall comply with 404, except that if the approach is to the latch side of the compartment door, clearance between the door side of the...
-
Auditorium accessible seating
Front or back approach from an accessible route requires a floor area of 36” x 48” for the wheelchair (ref: 2010 ADA Standards 802.1.3). ...
-
Elevator Car Controls
It also provides an exception that allows a maximum height of 54 inches for elevators with more than 16 openings where a parallel approach to the car controls is provided....
-
1133B.2.4.2
They are less stringent than 2013 CBC 404.2.4.1 for swinging doors approached from the hinge side on the "push" side [2010 CBC Fig. 11B-26A(b)], and 2013 CBC 404.2.4.2 for sliding doors...
-
Treatment of "manually-powered mobility aids.'' (Section-by-Section Analysis)
The NPRM queried whether the Department should maintain this approach to manually-powered mobility aids or whether it should adopt a more formal definition....
-
Treatment of ‘‘manually-powered mobility aids.'' (Section-by-Section Analysis)
The NPRM queried whether the Department should maintain this approach to manually powered mobility aids or whether it should adopt a more formal definition....
-
2. Comparison of Proposed Rule with EN 301 549 Standard
This standard supports an approach to communication known as “total communication.” We are not proposing to adopt this approach....
-
602 Drinking Fountains
section include: removal of references to water coolers (602.1) requiring all wheelchair accessible drinking fountains to provide knee and toe clearance for a forward approach...
-
Sinks [F212.3, Exception 2]
This is especially important if a forward approach is provided....
-
7. Clear Width
Are accessible guestrooms arranged so that persons who use wheelchairs, crutches and other mobility aids can approach and use beds; bathrooms; closets; heating, air conditioning and drapery...
-
4.16.2 Clear Floor Space
In order to accommodate independent wheelchair use, guidelines for clear floor space in ADAAG vary according to path of approach to the toilet....
-
403.5.2 Clear Width at Turn
Where the accessible route makes a 180 degree turn around an element which is less than 48 inches (1220 mm) wide, clear width shall be 42 inches (1065 mm) minimum approaching the turn, 48...
-
604.8.2.2 Doors
Toilet compartment doors, including door hardware, shall comply with 404, except that if the approach is to the latch side of the compartment door, clearance between the door side of the...
- Steelcase Series 5 Height-Adjustable Work Surface
-
606.2 Sink Clear Floor Space
Is forward approach to sinks located in common use employee break rooms consisting of micorwaves, toaster, and refrigerator required?...
-
Section 36.405 Alterations: Historic Preservation
No substantive change in the Department’s approach in this area is intended by this revision....
-
403.5.2 Clear Width at Turn
Where the accessible route makes a 180 degree turn around an element which is less than 48 inches (1220 mm) wide, clear width shall be 42 inches (1065 mm) minimum approaching the turn, 48...
-
11B-231.4.1 Cubicles and counters
Where counters are provided, at least one shall comply with Section 11B-904.4.2 _|Forward Approach|_ on both the visitor and detainee sides....
-
G.6.ii. - Why isn't undue burden more completely defined in the regulations?
The FAR rule also follows this approach....