accessibility to individuals with disabilities, any obstacles to the use of a method that could provide better service to individuals with disabilities, the safety and reliability of the approach...
Search Results "Approach"
Commonly Searched Documents
-
§ 37.42(d)(3)(iv)
-
E202.3 Federal Contracts (Section-by-Section Analysis)
This proposed exception is unchanged from existing 508 Standards § 1194.3(b), and the Board’s approach is discussed in greater detail above in Section IV.E.8 (Rulemaking History – 2010 and...
-
Scoping [4.1.3(20)]
Specifications in 4.34.2 and 4.34.3 were modified in June 1993 to allow either a forward or side approach and to provide further guidance on side reach heights....
-
ENTRANCE
An entrance includes the approach walk, the vertical access leading to the entrance platform, the entrance platform itself, vestibules if provided, the entry door(s) or gate(s), and the...
-
§ 37.42(d)(3)(iv)
accessibility to individuals with disabilities, any obstacles to the use of a method that could provide better service to individuals with disabilities, the safety and reliability of the approach...
-
A. Executive Orders 12866 and 13563—Summary of Regulatory Assessment
Executive Orders 12866 and 13563 direct agencies to assess all costs and benefits of available regulatory alternatives and, if regulation is necessary, to select regulatory approaches that...
-
Requirement 5. Light switches, electrical outlets, thermostats and other environmental controls in accessible locations.
If the reach is over an obstruction (for example, an overhanging shelf) between 20 and 25 inches in depth, the maximum height is reduced to 44 inches for forward approach; or 46 inches for...
-
9. Broadening of Documentation Requirement for Undue Burden Exception
We did not receive any comments directly related to this approach, but did receive a few comments requesting clarification of the factors to be addressed in the determination of undue burden...
-
1014.2.1.1 Clear Ground Space
The clear ground space shall be 36 inches (915 mm) minimum by 48 inches (1220 mm) minimum and shall be positioned for a parallel approach to the camp shelter. ...
-
R406.3 Unobstructed Side Reach
Where a clear space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 1220 mm (4.0 ft) maximum and the low side reach shall be 380...
-
Section 2. Accessible
Accessible", when used with respect to the public and common use areas of a building containing covered multifamily dwellings, means that the public or common use areas of the building can be approached...
-
1014.2.1.1 Clear Ground Space
The clear ground space shall be 36 inches (915 mm) minimum by 48 inches (1220 mm) minimum and shall be positioned for a parallel approach to the camp shelter....
- Armor-Tile Tactile Systems Cast In Place Detectable Warning Surface System
- Alertus Voice Public Address System Interface
-
Factors to Consider in Planning For & Administering an ADA Facilities Compliance Plan
Second, the size, type, and geographic separateness of your facilities should affect your approach....
-
Wheelchair Space for Seat Transfer
The proposed rule specified that the wheelchair space be positioned so that it provides a parallel approach to an end of the bench seat (903.2)....
-
1015.2 Clear Ground Space
The clear ground space shall be 36 inches (915 mm) minimum by 48 inches (1220 mm) minimum and shall be positioned for either a forward or parallel approach to the viewing location. ...
-
J2
If the drinking fountain is a floor-mounted unit, is there clear floor space at least 30 inches long x 48 inches wide (60 inches if it is in an alcove) for a side approach to the drinking...
-
4.1.6(1)(h) Entrances
indicating the location of the nearest accessible entrance(s) shall be installed at or near the inaccessible entrance, such that a person with disabilities will not be required to retrace the approach...
-
1015.2 Clear Ground Space
The clear ground space shall be 36 inches (915 mm) minimum by 48 inches (1220 mm) minimum and shall be positioned for either a forward or parallel approach to the viewing location....
-
Elevator Car Controls
It also provides an exception that allows a maximum height of 54 inches for elevators with more than 16 openings where a parallel approach to the car controls is provided....
-
1133B.2.4.2
They are less stringent than 2013 CBC 404.2.4.1 for swinging doors approached from the hinge side on the "push" side [2010 CBC Fig. 11B-26A(b)], and 2013 CBC 404.2.4.2 for sliding doors...
-
Treatment of "manually-powered mobility aids.'' (Section-by-Section Analysis)
The NPRM queried whether the Department should maintain this approach to manually-powered mobility aids or whether it should adopt a more formal definition....
-
Treatment of ‘‘manually-powered mobility aids.'' (Section-by-Section Analysis)
The NPRM queried whether the Department should maintain this approach to manually powered mobility aids or whether it should adopt a more formal definition....