Exception: In detention or correctional facilities, drinking fountains only serving holding or housing cells not required to comply with Section 11B-232 shall not be required to comply with...
Search Results "State Requirement"
-
11B-211.1 General
-
11B-208.2 Minimum number
Parking spaces complying with Section 11B-502 shall be provided in accordance with Table 11B-208.2 except as required by Sections 11B-208.2.1, 11B-208.2.2, and 11B-208.2.3....
-
232 Detention and Correctional Facilities
location (604.5) Scoping provisions for detention and correctional facilities require access to at least 2% of the general housing and holding cells provided (232.2.1)....
-
Issue: "Grandfather" Clause or Small Entity Exemption
Requirement: There is no “grandfather” clause in the ADA. However, the law is flexible....
-
11B-219.3 Receivers
Where a building contains more than one assembly area and the assembly areas required to provide assistive listening systems are under one management, the total number of required receivers...
-
Captioning at sporting venues. (Section-by-Section Analysis)
However, the Department requests public comment about the effect of requiring captioning of emergency announcements in all stadiums, regardless of size....
-
E.2. - Where an agency uses a best value "trade-off" source selection process, may it trade off applicable technical provisions of the Access Board’s standards where an offer provides strong technical merit, strong past performance, or a lower price?
The Access Board’s technical provisions are mandatory requirements that must be met (directly or through equivalent facilitation) unless (a) the product or service (if it is a commercial...
-
Captioning at sporting venues. (Section-by-Section Analysis)
Therefore, the Department is proposing requiring that sports stadiums with a capacity of 25,000 or more provide captioning for patrons who are deaf or hard of hearing for safety and emergency...
-
B. Patient Protection and Affordable Care Act and Section 510 of the Rehabilitation Act
Section 510 of the Rehabilitation Act requires the standards to be issued not later than 24 months after the enactment of the Patient Protection and Affordable Care Act....
-
11B-208.2 Minimum number
Parking spaces complying with Section 11B-502 shall be provided in accordance with Table 11B-208.2 except as required by Sections 11B-208.2.1, 11B-208.2.2, and 11B-208.2.3....
-
11B-219.3 Receivers
Where a building contains more than one assembly area and the assembly areas required to provide assistive listening systems are under one management, the total number of required receivers...
-
11B-219.3 Receivers
Exceptions: Where a building contains more than one assembly area and the assembly areas required to provide assistive listening systems are under one management, the total number...
-
General Issues
Technical and Functional Performance Criteria Section 508 (a)(2)(A)(ii) requires the Board to develop technical and functional performance criteria necessary to implement the requirements...
-
Safe harbor for qualified small businesses. (Section-by-Section Analysis)
The 2010 Standards go a long way toward meeting the concern of small businesses with regard to achieving compliance with both Federal and State accessibility requirements, because the Access...
-
Limited-Use/Limited-Application Elevators, Destination-Oriented Elevators and Private Residence Elevators
If a facility is exempt from the scoping requirement, but nonetheless installs an elevator, the 1991 Standards require the elevator to comply with the technical requirements for elevators...
-
Trailhead Information Signs [F216.13 and 1017.10]
This requirement applies to new trailhead information signs regardless of whether the newly constructed or altered trail complies with the technical requirements for trails....
-
Amenities
Clear floor or ground spaces required at exercise machines and equipment shall be permitted to overlap. Sauna doors are still required to provide access to wheelchair users....
-
1022.9 Stairway identification signs
They are required at enclosed stairs in buildings with more than 3 stories above or below the level of exit discharge. They are not required to be, and should not be tactile. ...
-
206.2.3 Multi-Story Buildings and Facilities
Spaces and elements located on a level not required to be served by an accessible route must fully comply with this document....
-
Picnic Tables
Practically speaking, tables up to 9 feet (2.74 meters) long usually require one space....
- Savaria Orion Limited Use/Limited Application Elevator
-
General: ADA Standard Section 404.1
Section 404.1 of the ADA Standards covers information in the current ADA Standards for doors, doorways, and gates that are part of an accessible route.
-
Check-Out Aisles: ADA Standard Section 216.11
Section 216.11 covers scoping requirements in the current ADA Standards for signs at check-out aisles.
-
Clear Width at Turn: ADA Standard Section 403.5.2
Section 403.5.2 covers the current ADA Standards for the clear width at a turn on walking surfaces that are part of an accessible route.