Hand-activated door latching, locking and opening hardware shall be centered between 30 inches (762 mm) and 44 inches (1118 mm) above the floor....
Search Results "Usable Door (FHA)"
-
1132A.8 Hand-activated door hardware
-
1132A.8 Hand-activated door hardware
Hand-activated door latching, locking and opening hardware shall be centered between 30 inches (762 mm) and 44 inches (1118 mm) above the floor....
-
1132A.3, Item 5
A pair of doors, manual or automatic, must have at least one leaf which provides a clear width of not less than 32 inches (813 mm), measured with the door positioned at an angle of 90 degrees...
-
1132A.3, Item 5
A pair of doors, manual or automatic, must have at least one leaf which provides a clear width of not less than 32 inches (813 mm), measured with the door positioned at an angle of 90 degrees...
-
11B-404.2.7 Door and gate hardware
Where sliding doors are in the fully open position, operating hardware shall be exposed and usable from both sides. [Safe Harbor only applies to existing primary entrances.]...
-
11B-213.3.1.2 Toilet compartments with urinal compartments
At all compartments not required to comply with Section 11B-604.8 or Section 11B-605.5, compartment doors shall be in-swinging and self-closing....
-
11B-213.3.1.2 Toilet compartments with urinal compartments
At all compartments not required to comply with Section 11B-604.8 or Section 11B-605.5, compartment doors shall be in-swinging and self-closing....
-
4.1.2(7)
(7) Doors: (a) At each accessible entrance to a building or facility, at least one door shall comply with 4.13....
-
Compliance Determinations by State and Local Jurisdictions
Comment. A few commenters questioned the role of States and units of local government in determining compliance with the Act's accessibility requirements. The commenters noted that...
-
Door Clear Width
Door Clear Width Open the door 90 degrees, measure from the face of the door to the edge of the door stop....
-
Guidelines for Requirement 6
However, as will be discussed more fully in the following section concerning the Guidelines for Requirement 7 (Usable Bathrooms), reinforcement for shower seats would provide adaptability...
-
703.4.2 Location
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side....
-
Controls [§404.3.5]
Controls [§404.3.5] Door and gate controls must be compliant as operable parts (operable with one hand and without tight grasping, pinching, twisting of the wrist, or more than 5 lbf)...
-
Entrances
space beyond the latch side of the door....
-
Supplementary Information:
13, 1991, in a manner that makes them inaccessible to persons with disabilities, and established design and construction requirements to make these dwellings readily accessible to and usable...
-
Are spring hinges and gravity hinges considered “closers” in determining the size of maneuvering clearances?
Some approaches require additional maneuvering clearances when a door or gate is equipped with a closer because of the additional force that must be counteracted in proceeding through doors...
-
Technical Memorandum TM 2017-25 Door and Gate Surfaces
TAS 404.2.10 also includes Exceptions for (1) sliding doors, (2) tempered glass doors (3) doors and gates which do not extend to within 10 inches of the finish floor, and (4) existing doors...
-
H25
Is the clear width of the door at least 32 inches (measured between the face of the door and the edge of the opening) when the door is open 90 degrees?...
-
Floor or Ground Surface: ADA Standard Section 404.2.4.4
Section 404.2.4.4 covers the current ADA Standards for floor or ground surfaces at door maneuvering clearances.
-
Doors, Doorways, and Gates
Section 206.5 provides scoping requirements for doors, doorways, and gates....
-
1132A.3, Item 3
Swinging doors shall be capable of opening at least 90 degrees....
-
1132A.3, Item 3
Swinging doors shall be capable of opening at least 90 degrees....
-
11B-404.3.2 Maneuvering clearance
Clearances at power-assisted doors and gates shall comply with Section 11B-404.2.4....
-
11B-404.3.2 Maneuvering clearance
Clearances at power-assisted doors and gates shall comply with Section 11B-404.2.4....