Clarifies in the exception the technical requirements for accessible residential dwelling units when alterations are made to existing public housing facilities are technically infeasible...
Search Results "Residential Amenity Center"
-
11B-233.3.4 Alterations
-
11B-809.10.6.3 Clearance
From DSA's "Summary of New and Amended 2025 California Building Code (CBC) Regulations for Accessibility in the Triennial Code Cycle": "Amendments increase clear floor space at showers in residential...
-
602.2 Clear Floor Space
Units shall have a clear floor or ground space complying with 305 positioned for a forward approach and centered on the unit....
-
602.2 Clear Floor Space
Units shall have a clear floor or ground space complying with 305 positioned for a forward approach and centered on the unit....
-
11B-602.2 Clear floor space
Units shall have a clear floor or ground space complying with Section 11B-305 positioned for a forward approach and centered on the unit....
-
11B-602.2 Clear floor space
Units shall have a clear floor or ground space complying with Section 11B-305 positioned for a forward approach and centered on the unit....
-
804.3 Kitchen Work Surface
In residential dwelling units required to comply with 809, at least one 30 inches (760 mm) wide minimum section of counter shall provide a kitchen work surface that complies with 804.3....
-
11B-804.3 Kitchen work surface
In residential dwelling units required to comply with Section 11B-809, at least one 30 inches (762 mm) wide minimum section of counter shall provide a kitchen work surface that complies...
-
11B-804.3 Kitchen work surface
In residential dwelling units required to comply with Section 11B-809, at least one 30 inches (762 mm) wide minimum section of counter shall provide a kitchen work surface that complies...
-
602.2 Clear Floor Space
Units shall have a clear floor or ground space complying with 305 positioned for a forward approach and centered on the unit....
-
804.3.1 Clear Floor or Ground Space
The clear floor or ground space shall be centered on the kitchen work surface and shall provide knee and toe clearance complying with 306....
-
11B-604.3.2 Overlap
Exception: In residential dwelling units, a lavatory complying with Section 11B-606 shall be permitted on the rear wall 26 inches (660 mm) minimum from the water closet centerline to allow...
-
11B-604.3.2 Overlap
Exception: In residential dwelling units, a lavatory complying with Section 11B-606 shall be permitted on the rear wall 26 inches (660 mm) minimum from the water closet centerline to allow...
-
804.3.1 Clear Floor or Ground Space
The clear floor or ground space shall be centered on the kitchen work surface and shall provide knee and toe clearance complying with 306....
-
11B-804.3.1 Clear floor or ground space
The clear floor or ground space shall be centered on the kitchen work surface and shall provide knee and toe clearance complying with Section 11B-306....
-
11B-602.2 Clear floor space
Units shall have a clear floor or ground space complying with Section 11B-305 positioned for a forward approach and centered on the unit....
-
11B-804.3.1 Clear floor or ground space
The clear floor or ground space shall be centered on the kitchen work surface and shall provide knee and toe clearance complying with Section 11B-306....
-
11B-804.3.1 Clear floor or ground space
The clear floor or ground space shall be centered on the kitchen work surface and shall provide knee and toe clearance complying with Section 11B-306....
-
11B-607.4 Grab bars
In residential dwelling units, grab bars shall not be required to be installed in bathtubs located in bathing facilities provided that reinforcement has been installed in walls and located...
-
11B-607.4 Grab bars
In residential dwelling units, grab bars shall not be required to be installed in bathtubs located in bathing facilities provided that reinforcement has been installed in walls and located...
-
F233.2 Residential Dwelling Units Provided by HUD or Through Grant or Loan Programs Administered by HUD
Where facilities with residential dwelling units are provided by the Department of Housing and Urban Development (HUD), or through a grant or loan program administered by HUD, residential...
-
804.3.1 Clear Floor or Ground Space
The clear floor or ground space shall be centered on the kitchen work surface and shall provide knee and toe clearance complying with 306....
-
608.3 Grab Bars (Exception 2)
608.3 Grab Bars (Exception 2) Exception 2 to this section permits grab bars to not be installed in shower compartments in residential dwelling units required to provide mobility features...
-
607.4 Grab Bars (Exception 2)
607.4 Grab Bars (Exception 2) Exception 2 to this section permits grab bars to not be installed at bathtubs in residential dwelling units required to provide mobility features provided...