Bathtubs required to be accessible shall comply with this section.
Search Results "Dwelling (FHA)"
-
1134A.5 Bathtubs
-
1133A.5 Lower shelving
Lower shelving and/or drawer space shall be provided in the kitchen at a height of no more than 48 inches (1219 mm) above the floor.
-
1132A.4.1, Item 1
1. Thresholds with a change in height of not more than ¼ inch (6.35 mm) may be vertical.
-
1133A.2.1 Clear width
Kitchens shall have a minimum clear width measured between any cabinet, countertop or the face of any appliance (excluding handles and controls) that projects into the kitchen and...
-
1136A.1 Receptacle heights
Electrical receptacle outlets on branch circuits of 30 amperes or less and communication system receptacles shall be located no more than 48 inches (1219 mm) measured from the top of...
-
1136A.1 Receptacle heights
Electrical receptacle outlets on branch circuits of 30 amperes or less and communication system receptacles shall be located no more than 48 inches (1219 mm) measured from the top of...
-
1134A.5 Bathtubs
Bathtubs required to be accessible shall comply with this section. 1. Floor space. There shall be a minimum clear floor space 48 inches parallel by 30 inches perpendicular (1219...
-
1132A.7 Type of lock or latch
The type of latch and lock required for all doors shall be in accordance with Section 1132A.8 and Chapter 10, Section 1008.
-
1133A.5 Lower shelving
Lower shelving and/or drawer space shall be provided in the kitchen at a height of no more than 48 inches (1219 mm) above the floor.
-
1132A.8 Hand-activated door hardware
Hand-activated door latching, locking and opening hardware shall be centered between 30 inches (762 mm) and 44 inches (1118 mm) above the floor. Latching and locking doors that are...
-
1133A.2.1 Clear width
Kitchens shall have a minimum clear width measured between any cabinet, countertop or the face of any appliance (excluding handles and controls) that projects into the kitchen and...
-
F228.2 Mail Boxes
In residential facilities, where mail boxes are provided for each residential dwelling unit, mail boxes complying with 309 shall be provided for each residential dwelling unit required to...
-
228.2 Mail Boxes
In residential facilities, where mail boxes are provided for each residential dwelling unit, mail boxes complying with 309 shall be provided for each residential dwelling unit required to...
-
11B-233.1 General
This section addresses long-term living (non-transient), public housing dwelling units....
-
11B-233.1 General
This section addresses long-term living (non-transient), public housing dwelling units....
-
228.2 Mail Boxes
In residential facilities, where mail boxes are provided for each residential dwelling unit, mail boxes complying with 309 shall be provided for each residential dwelling unit required to...
-
11B-809.10.6.1 Size
When one or more shower stalls are provided within the same dwelling unit, at least one shower stall shall comply with one of the following: A transfer type shower compartment...
-
Are multi-unit dwellings of any kind covered under the requirements? Our thinking stemmed from the fact that it covers public housing, but how is public housing defined? For example, is section 8 housing applicable? Are all condos and apartments applicable if they are providing charging for any of their residents and not just a specific resident?
RESPONSE: Privately owned multi-family dwellings are not subject to the new CBC Chapter 11B accessibility requirements for EVCS....
-
11B-804.3 Kitchen work surface
In residential dwelling units required to comply with Section 11B-809, at least one 30 inches (762 mm) wide minimum section of counter shall provide a kitchen work surface that complies...
-
11B-804.3 Kitchen work surface
In residential dwelling units required to comply with Section 11B-809, at least one 30 inches (762 mm) wide minimum section of counter shall provide a kitchen work surface that complies...
-
11B-233.3.1.2.2 Non-elevator buildings
Ground floor residential dwelling units in non-elevator buildings shall be adaptable....
-
11B-233.3.1.2.2 Non-elevator buildings
Ground floor residential dwelling units in non-elevator buildings shall be adaptable....
-
11B-233.3.4 Alterations
unit, the entity shall be permitted to alter or construct a comparable residential dwelling unit to comply with 809.2 through 809.4 provided that the minimum number of residential dwelling...
-
228 Depository, Vending Machines, Change Machines, Mail Boxes and Fuel Dispensers
In residential facilities, where mail boxes are provided for each residential dwelling unit, mail boxes complying with 309 shall be provided for each residential dwelling unit required to...