The length of transfer supports shall comply with M305.2.2.1 or M305.2.2.2.
Search Results "Aisle Chair"
Commonly Searched Documents
-
M305.2.2 Length
-
5.3.1 Permitted Obstructions to Transfer Sides for M301 and M302
The provision will coincide with the seat area design of most examination chairs. NPRM Proposed Provision: M301.2.3 and M302.2.3 Transfer Sides....
- Midmark 625 Barrier-Free® Power Examination Table
- Midmark 623 Barrier-Free® Power Examination Table
- Midmark Ritter 222 Barrier-Free® Power Examination Table
- Midmark Ritter 223 Barrier-Free® Power Examination Table
-
36 CFR Part 1195 Proposed Accessibility Standards for Medical Diagnostic Equipment NPRM - Preamble
The proposed standards contain minimum technical criteria to ensure that medical diagnostic equipment, including examination tables, examination chairs, weight scales, mammography equipment...
- Access Board: Accessible Passenger Loading Zones
-
Re: 11B-502.3.3 Marking
Is ISA symbol 36 x 36" include a white border or is the blue field to be a min. of 36 x 36 and a white border only an option?
-
Standards Specific to Assembly Areas
• Note: This means that access to a wheelchair space cannot be through another wheelchair space, nor can the wheelchair space stick out into the aisle....
-
M305.2.8 Fittings
Transfer supports shall not rotate within their fittings when in place for transfer.
-
M305.2.7 Clearance
Clearance between the transfer support gripping surface and adjacent surfaces or obstructions shall be 1 ½ inches (38 mm) minimum.
-
M305.2.7 Clearance (Section-by-Section Analysis)
In the MDE NPRM, the Access Board did not provide any specific requirements for clearances around the transfer support. However, in the preamble to the MDE NPRM the Access Board...
-
5.4.10 Transfer Support Fittings Recommendations for M301 and M302
5.4.10 Transfer Support Fittings Recommendations for M301 and M302 Description: To ensure safe and effective transfers, transfer supports must not rotate within their fittings...
-
5.4.10 Transfer Support Fittings for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.10 Transfer Support Fittings for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position. The transfer supports shall not rotate when locked in place for patient...
-
Attachment A: Disability-Related Issues for Emergency Plan Coordinators
(Give a copy of this checklist to personnel who are responsible for creating, reviewing, maintaining, practicing and revising emergency plans.) DISABILITY-RELATED ISSUES FOR...
-
M305.2.3 Fittings
Transfer supports shall not rotate within their fittings.
- Brewer Access™ High-Low Exam Table
-
2.1 Parking
Are there accessible parking spaces (8 feet wide for car plus 5-foot wide access aisle)? Are there usable ramps or curb cuts onto the sidewalks?...
-
M305.2.1 Location
Transfer supports shall comply with M305.2.1.1 or M305.2.1.2 and shall be located 1 ½ inches (38 mm) maximum measured horizontally from the plane defined by the nearest edge of the...
-
M305.2.4 Cross Section
Transfer supports shall have a cross section complying with 305.2.4.1 or 305.2.4.2.
-
M305.2.3 Height
During use, the tops of transfer support gripping surfaces shall be 6 inches (150 mm) minimum and 19 inches (485 mm) maximum higher than the top of the associated uncompressed...
-
M305.2.6 Gripping Surface
Transfer support gripping surfaces shall be continuous along their length and shall not be obstructed along their tops or sides. The bottoms of transfer support gripping surfaces...
-
M305.2.6 Gripping Surfaces (Section-by-Section Analysis)
The proposed rule did not provide any specific requirements regarding gripping surfaces on transfer supports. However, in the MDE NPRM preamble the Access Board repeatedly noted that...