To make a protruding object detectable: Place an object or a barrier below the protruding object in the cane-detectable area not more than 27 inches above the floor....
-
TEST NO. 3 – UNUSUAL CHARACTERISTICS TEST
include sites located in a state or federally designated floodplain or coastal high-hazard areas and sites subject to other similar requirements of law or code that require the lowest floor...
-
11B-608.3 Grab bars
Where multiple grab bars are used, required horizontal grab bars shall be installed at the same height above the finish floor....
-
TEST NO. 3 – UNUSUAL CHARACTERISTICS TEST
include sites located in a state or federally designated floodplain or coastal high-hazard areas and sites subject to other similar requirements of law or code that require the lowest floor...
-
11B-608.3 Grab bars
Where multiple grab bars are used, required horizontal grab bars shall be installed at the same height above the finish floor....
- Ampetronic MLD9 MultiLoop Driver Hearing System
-
Large Print (Advisory Guidance)
Use only left margin justification to maintain uniform spacing across lines. Right margin justification can produce uneven spacing between letters and words....
-
Section 307 Protruding Objects
This dryer protrudes more than 4" from the wall and is greater than 27" above the finish floor. Isn't this a violation of Section 307 Protruding Objects?...
-
608.7 Thresholds
maximum shall be permitted in transfer type shower compartments in existing facilities where provision of a ½ inch (13 mm) high threshold would disturb the structural reinforcement of the floor...
-
604.9.6 Dispensers
The outlet of the dispenser shall be 14 inches (355 mm) minimum and 19 inches (485 mm) maximum above the finish floor....
-
M302.4.2 Clearance Around Base
The base of the diagnostic equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the examination...
-
M301.4.2 Clearance Around Base
The base of diagnostic equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the examination...
-
608.5.1 Transfer Type Shower Compartments
compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1220 mm) maximum above the shower floor...
-
610.2 Bathtub Seats
The top of bathtub seats shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the bathroom finish floor....
-
MEASUREMENT TECHNIQUE
MEASUREMENT TECHNIQUE The depth and width are measured along the centerlines of the seat, and the height from the floor to the highest point of the transfer surface: The depth...
-
608.7 Thresholds
maximum shall be permitted in transfer type shower compartments in existing facilities where provision of a ½ inch (13 mm) high threshold would disturb the structural reinforcement of the floor...
-
E2-c
Remove or relocate the object or place a detectable object on the floor below each object to remove the hazard....
-
608.5.1 Transfer Type Shower Compartments
compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1220 mm) maximum above the shower floor...
-
1132A.4, Item 3
Changes in height greater than ½ inch (12.7 mm) shall be accomplished by means of a ramp complying with Section 1114A or by means of a platform constructed to the level of the floor as illustrated...
-
4.9.4(2)
At the top, the extension shall be parallel with the floor or ground surface....
-
3.4.3 Unrestricted Viewing Opportunities
section 3.4.1 shall provide at least one unrestricted viewing opportunity that accommodates eye levels between 32 inches (815 mm) minimum and 51 inches (1295 mm) maximum above the ground or floor...
-
11B-411.2.3.2 Car designation signs
Car designation signs complying with Sections 11B-703.2 and 11B-703.4.1 shall be provided on both jambs of the hoistway immediately below the floor designation....
-
Signatures
MOSES ASSISTANT UNITED STATES ATTORNEY DISTRICT OF CONNECTICUT United States Attorney's Office 157 Church Street, 25th Floor New Haven, CT 06510 (203) 821-3700 Date: 12/22/15...