Designed to fit neatly into standard double-gang electrical boxes Push area and back plate are combined for a slim design Crafted in heavy gauge stainless steel for a durable...
Search Results "Clear Floor Area"
- BEA Inc. PBS2G Series 4.5" Square Push Plate (Push to Open)
-
§ 36.303(g)(5) Performance requirements for captioning devices and audio description devices
Captioning devices must be adjustable so that the captions can be viewed as if they are on or near the movie screen, and must provide clear, sharp images in order to ensure readability of...
-
§ 36.303(g)(5) Performance requirements for captioning devices and audio description devices
Captioning devices must be adjustable so that the captions can be viewed as if they are on or near the movie screen, and must provide clear, sharp images in order to ensure readability of...
-
11B-406.6 Islands
The clear width of the accessible route at islands shall be 60 inches (1524 mm) wide minimum. Where curb ramps are provided, they shall comply with Section 11B-406....
-
608.2.1 Transfer Type Shower Compartments
Transfer type shower compartments shall be 36 inches (915 mm) by 36 inches (915 mm) clear inside dimensions measured at the center points of opposing sides and shall have a 36 inch (915...
-
1009.5.2 Transfer Space
Figure 1009.5.2 Clear Deck Space at Transfer Platform...
-
§35.150(d)(2)
(2) If a public entity has responsibility or authority over streets, roads, or walkways, its transition plan shall include a schedule for providing curb ramps or other sloped areas where...
-
11B-505.3 Continuity
Exception: In assembly areas, ramp handrails adjacent to seating or within the aisle width shall not be required to be continuous in aisles serving seating....
-
Formats for Announcements and Messages
Email, text message, social media channels, telephone-accessed schedule announcements, voicemail, hotel meeting area video text, sleeping room video text via television, written postings...
-
§ 35.150(d)(2)
(2) If a public entity has responsibility or authority over streets, roads, or walkways, its transition plan shall include a schedule for providing curb ramps or other sloped areas where...
-
11B-505.3 Continuity
Exception: In assembly areas, ramp handrails adjacent to seating or within the aisle width shall not be required to be continuous in aisles serving seating....
-
§ 37.163(e)
the transportation service the entity is able to provide, the public entity may keep the vehicle in service with an inoperable lift for no more than five days (if the entity serves an area...
-
1132A.5.2 Strike edge maneuvering space at doors
The width of the level area on the side to which the door swings shall extend 18 inches (457 mm) past the strike edge for all doors....
-
1134A.7, Item 4
Water closet controls shall be mounted no more than 44 inches (1118 mm) above the floor. The force required to activate controls shall be no greater than 5 pounds (22.2 N)....
-
11B-903.6 Structural strength
Benches shall be affixed to the wall or floor....
-
3. Folding Seat
Do the roll-in showers have a securely fastened folding seat at 17"-19" above the floor onto which persons who use wheelchairs may transfer to shower?...
-
AUTOMATIC DOOR
The switch that begins the automatic cycle may be a photoelectric device, floor mat or manual switch....
-
4.17.4 Toe Clearances
In standard stalls, the front partition and at least one side partition shall provide a toe clearance of at least 9 in (230 mm) above the floor....
-
Height [4.18.2]
Height [4.18.2] The rim of an accessible urinal must be no higher than 17 inches above the finished floor....
-
4.17.4 TOE CLEARANCES
In standard stalls, the front partition and at least one side partition shall provide a toe clearance of at least 9 in (230 mm) above the floor....
-
4.1.7(2)(e)
., books, should be no higher than 44 in (1120 mm) above the floor surface....
-
1132A.10 Door signal devices
The activating mechanism shall be mounted a maximum of 48 inches (1219 mm) above the floor and connected to permanent wiring....
-
1134A.7, Item 4
Water closet controls shall be mounted no more than 44 inches (1118 mm) above the floor. The force required to activate controls shall be no greater than 5 pounds (22.2 N)....
-
§ 38.79(b)
(b) All thresholds and step edges shall have a band of color(s) running the full width of the step or threshold which contrasts from the step tread and riser or adjacent floor, either light-on-dark...