Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
Search Results "Functional Space"
-
308.2.2 Obstructed High Reach
-
Openings [1018.6]
Gaps, including spaces between the planks on a boardwalk and drainage holes in temporary or permanent surfaces, that are big enough for wheels, canes, or crutch tips to drop through or become...
-
R212 Street Furniture (Section-by-Section Analysis)
At least 50 percent, but no less than one, of benches at each location must provide a clear space for a wheelchair adjacent to the bench. Benches at tables are not required to comply....
-
T704.2.1 Audible and visible notification
Visible components shall illuminate or activate with a stop request, be viewable onboard from all wheelchair spaces and priority seats for passengers with disabilities, and extinguish when...
-
J. Valet Parking and New Parking Garage
Defendants agree to construct accessible parking spaces, entrances, and routes of travel as required by 2010 Standards §§ 208.1, 208.2, 208.2.4, 208.3.1, and 502.1-503.5, and to erect appropriate...
-
Shared Use Paths
Shared use paths are physically separated from motor vehicle traffic by an open space or barrier, and are either within the highway right-of-way or within an independent right-of-way....
-
Meeting Room Layouts and Considerations
Those who use mobility aids, such as wheelchairs, scooters, walkers, crutches, and braces, require more space to move around....
-
Tactile Maps for Orientation and Way Finding
In addition, maps for orientation provide a big picture understanding of a whole geographic or environmental space for context....
-
11B-229.1 General
Where glazed openings are provided in accessible rooms or spaces for operation by occupants, at least one opening shall comply with Section 11B-309 _|Operable Parts|_....
-
11B-216.4.1 Exit doors
An exit passageway is a horizontal exit component that is separated from the interior spaces of the building by fire-resistance-rated construction and that leads to the exit discharge or...
-
1010.1.5 Floor elevation
Doors serving equipment spaces not required to be accessible in accordance with Section 11B-203.5 and serving an occupant load of five or less shall be permitted to have a landing on one...
-
11B-904.4 Sales and service counters
mail boxes, the counter shall be permitted to have a portion which is 24 inches (610 mm) long minimum complying with Section 11B-904.4.1 provided that the required clear floor or ground space...
-
11B-904.4 Sales and service counters
mail boxes, the counter shall be permitted to have a portion which is 24 inches (610 mm) long minimum complying with Section 11B-904.4.1 provided that the required clear floor or ground space...
-
11B-233.3.1.2.5 Multi-story residential dwelling units in buildings with no elevator
Rooms or spaces located on the primary entry level shall be served by an accessible route and comply with Sections 11B-809.6 through 11B-809.12....
-
206.2.15 Golf Facilities
At least one accessible route shall connect accessible elements and spaces within the boundary of the golf course....
-
810.6.2 Routes and Destinations
EXCEPTION: Where sign space is limited, characters shall not be required to exceed 3 inches (75 mm). Advisory 810.6.2 Routes and Destinations....
-
4. Assess During the Planning, Installation and Maintenance Phases
for entry/egress of equipment and required turning spaces....
-
5. Conforming Alternate Versions
The Department had learned from a number of sources that such alternate sites are often not well maintained, frequently lack all the functionality available on the non-conforming Web site...
-
Section 35.151(e) Social service center establishments
In the NPRM, the Department expressed concern that the residential facilities standards do not include a requirement for clear floor space next to beds similar to the requirement in the...
-
Section 35.151(e) Social service center establishments (Section-by-Section Analysis)
In the NPRM, the Department expressed concern that the residential facilities standards do not include a requirement for clear floor space next to beds similar to the requirement in the...
-
Section 4.1.3, Accessible Buildings: New Construction (Preamble, Section-by-Section Analysis)
In addition, if a building is designed to provide access to enclosed parking, pedestrian tunnels, or elevated walkways, at least one entrance that serves each such function must be accessible...
-
11B-212.3 Sinks
Where sinks are provided, at least 5 percent, but no fewer than one, of each type provided in each accessible room or space shall comply with Section 11B-606. Exceptions: 1....