Clear floor or ground space shall comply with 305....
Search Results "Standing Space"
Commonly Searched Documents
-
305.1 General
-
11B-305.1 General
Clear floor or ground space shall comply with Section 11B-305. ...
-
11B-305.1 General
Clear floor or ground space shall comply with Section 11B-305....
-
Can doors swing into required clear floor or ground space?
Doors cannot swing into required clear floor or ground spaces in these specific instances: clear floor space at controls for automatic and power assisted doors and gates (404.3.5...
-
11B-1008.4.2 Clear floor or ground space
Clear floor or ground space complying with Sections 11B-305.2 and 11B-305.3 shall be provided at play components. [2010 ADAS] Advisory 1008.4.2 Clear Floor or Ground Space. ...
-
1009.4.1 Clear Deck Space
1009.4.1 Clear Deck Space....
-
Lines of Sight Over Heads: ADA Standard Section 802.2.1.1
Where spectators are provided lines of sight over the heads of spectators seated in the first row in front of their seats, spectators seated in wheelchair spaces shall be afforded lines...
-
11B-802.2.1.1 Lines of sight over heads
Where spectators are provided lines of sight over the heads of spectators seated in the first row in front of their seats, spectators seated in wheelchair spaces shall be afforded lines...
-
11B-705.1.1.2 Dome spacing
Truncated domes in a detectable warning surface shall have a center-to-center spacing of 2.3 inches (58 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...
-
Perpendicular and Angled Parking Spaces (R309.3) (Section-by-Section Analysis)
Perpendicular and Angled Parking Spaces (R309.3) (Section-by-Section Analysis) An access aisle must be provided at street level for the entire length of each accessible perpendicular...
-
§ 38.125(d)(2) Wheelchair or mobility aid spaces
(2) Wheelchair or mobility aid spaces. Spaces for persons who wish to remain in their wheelchairs or mobility aids shall have a minimum clear floor space 48 inches by 30 inches....
-
Ground Level: ADA Standard Section 1008.2.4.1
In play areas less than 1000 square feet (93 m2), the clear width of accessible routes shall be permitted to be 44 inches (1120 mm) minimum, if at least one turning space complying with...
-
11B-1008.2.4.1 Ground level
Exceptions: In play areas less than 1000 square feet (93 m2), the clear width of accessible routes shall be permitted to be 44 inches (1118 mm) minimum, if at least one turning space...
-
4.33.2* Size of Wheelchair Locations
Each wheelchair location shall provide minimum clear ground or floor spaces as shown in Fig. 46....
-
4.33.2* SIZE OF WHEELCHAIR LOCATIONS
Each wheelchair location shall provide minimum clear ground or floor spaces as shown in Fig. 46....
-
1014.2.1.1 Clear Ground Space
A clear ground space shall be provided at the entrance to the camp shelter. ...
-
1014.2.1.1 Clear Ground Space
A clear ground space shall be provided at the entrance to the camp shelter....
-
Parking Spaces for Vehicles Other Than RVs [F244.2.3.2.2]
Parking spaces for vehicles other than RVs within camping units with mobility features must comply with the following technical requirements for width, surface, and slope....
-
305.5 Position
Unless otherwise specified, clear floor or ground space shall be positioned for either forward or parallel approach to an element....
-
11B-705.1.1.2 Dome spacing
Truncated domes in a detectable warning surface shall have a center-to-center spacing of 2.3 inches (58 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...
-
Lines of Sight Between Heads: ADA Standard Section 802.2.1.2
Where spectators are provided lines of sight over the shoulders and between the heads of spectators seated in the first row in front of their seats, spectators seated in wheelchair spaces...
-
11B-802.2.1.2 Lines of sight between heads
Where spectators are provided lines of sight over the shoulders and between the heads of spectators seated in the first row in front of their seats, spectators seated in wheelchair spaces...
-
11B-705.1.1.2 Dome spacing
11B-705.1.1.2 Dome spacing....
-
305.3 Size
The clear floor or ground space shall be 30 inches (760 mm) minimum by 48 inches (1220 mm) minimum....