4.17; where 6 or more stalls are provided, in addition to the stall complying with 4.17.3, at least one stall 36 in (915 mm) wide with an outward swinging, self-closing door and parallel grab...
Search Results "Shower Grab Bar"
Commonly Searched Documents
-
4.22.4 Water Closets
-
608.2.1 Transfer Type Shower Compartments
Transfer type shower compartments shall be 36 inches (915 mm) by 36 inches (915 mm) clear inside dimensions measured at the center points of opposing sides and shall have a 36 inch (915...
-
Railings—Guardrails, Handrails, and Safety
Terminology Tip What's the difference between a guardrail, a handrail, and a grab bar?...
-
Outdoor Rinsing Showers [1011.2, 1011.3, and 1011.7]
The shower pedestal or wall with the shower heads must be at the rear end of the clear ground space. At least one hand-held shower spray unit must be provided....
-
11B-608.7 Thresholds
Thresholds in roll-in type shower compartments shall be ½ inch (13 mm) high maximum in accordance with 303....
-
11B-608.7 Thresholds
Thresholds in roll-in type shower compartments shall be ½ inch (13 mm) high maximum in accordance with 303....
-
608.2 Size and Clearances for Shower Compartments
Shower compartments shall have sizes and clearances complying with 608.2....
-
608.2 Size and Clearances for Shower Compartments
Shower compartments shall have sizes and clearances complying with 608.2....
-
11B-809.10.6.3 Floor space
A clear maneuvering space 30 inches (762 mm) wide minimum by 48 inches (1219 mm) minimum in length shall be located outside the shower, with the width flush with the control wall and the...
-
11B-608.2 Size and clearances for shower compartments
11B-608.2 Size and clearances for shower compartments. Shower compartments shall have sizes and clearances complying with Section 11B-608.2....
-
608.2.2 Standard Roll-In Type Shower Compartments
608.2.2 Standard Roll-In Type Shower Compartments....
-
Alternate Roll-in Showers
Specifications are provided for alternate roll-in showers, including their size and the location of entries (608.2.3)....
-
11B-608.2.1 Transfer type shower compartments
mm) wide minimum entry on the face of the shower compartment....
-
608.2.2 Standard Roll-In Type Shower Compartments
Standard roll-in type shower compartments shall be 30 inches (760 mm) wide minimum by 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
- Delta Single Function Hand Shower with Grab Bar RPW124HDF
-
11B-608.7 Thresholds
Thresholds in roll-in type shower compartments shall be ½ inch (12.7 mm) high maximum in accordance with Section 11B-303....
-
11B-233.3.1.2.6.5 Additional requirements.
Grab bar reinforcement complying with Sections 11B-809.10.5.2, 11B-809.10.6.4, or 11B-809.10.7.3. 2. Interior door opening width complying with Section 11B-404.3.1. 3....
- Delta Adjustable Grab Bar 2-Setting Hand Shower 52001-UF
- Delta Adjustable Grab Bar 2-Setting Hand Shower 52003-UF
- Delta Adjustable Grab Bar 2-Setting Hand Shower 52002-DS
- Figure 1009.4.1 Clear Deck Space at Transfer Walls – Drawing from the U.S. Access Board
-
608.2.2 Standard Roll-In Type Shower Compartments
Standard roll-in type shower compartments shall be 30 inches (760 mm) wide minimum by 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
- Delta Adjustable Grab Bar 2-Setting Hand Shower 52003-DS
-
11B-608.2.2 Standard roll-in type shower compartments
11B-608.2.2 Standard roll-in type shower compartments....