4.1 This practice was developed specifically for estimating pathway roughness from longitudinal profile measurements. 4.2 Longitudinal profile measurements for one wheel track are transformed...
Search Results "Mitigating Measures"
-
4. Summary of Practice
-
11B-608.2.2 Standard roll-in type shower compartments
Standard roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
11B-604.7 Dispensers and disposal units
Toilet paper dispensers shall comply with 309.4 and shall be 7 inches (180 mm) minimum and 9 inches (230 mm) maximum in front of the water closet measured to the centerline of the dispenser...
-
11B-411.2.1.2.5 Audio output
Auditory volume shall be at least 10 dB above ambient sound level, but shall not exceed 80 dB, measured 36 inches (914 mm) in front of the console....
-
11B-604.7 Dispensers and disposal units
Toilet paper dispensers shall comply with 309.4 and shall be 7 inches (180 mm) minimum and 9 inches (230 mm) maximum in front of the water closet measured to the centerline of the dispenser...
-
11B-411.2.1.2.3 Accessibility function button
The dots shall be spaced ¼ inch (6.4 mm), measured center to center, in the form of an equilateral triangle with a vertex pointing up....
-
11B-411.2.1.2.3 Accessibility function button
The dots shall be spaced ¼ inch (6.4 mm), measured center to center, in the form of an equilateral triangle with a vertex pointing up....
-
11B-411.2.1.2.5 Audio output
Auditory volume shall be at least 10 dB above ambient sound level, but shall not exceed 80 dB, measured 36 inches (914 mm) in front of the console....
-
A. Accessible Voting Program
The City agrees that the following measures are reasonable and will be implemented where necessary to make an otherwise inaccessible polling place accessible on Election Day....
-
References:
IDeA Center (Buffalo Study) wheelbase measurements on wheeled mobility devices...
-
§100.143(e)
Not every corrective measure listed in paragraph (d) of this section need be taken for each likely violation....
-
§ 38.107(a)(2)
(2) The height of the water closet shall be 17 inches to 19 inches measured to the top of the toilet seat. Seats shall not be sprung to return to a lifted position....
-
§ 38.123(a)(2)
(2) The height of the water closet shall be 17 inches to 19 inches measured to the top of the toilet seat. Seats shall not be sprung to return to a lifted position....
-
§ 38.157(a)
(a) Any stepwell or doorway immediately adjacent to the driver shall have, when the door is open, at least 2 foot-candles of illumination measured on the step tread....
-
School Districts' Standards and Procedures
Specifically, the evaluation standards and procedures must ensure that: Evaluations consist of more than IQ tests;55 Evaluations measure specific areas of educational need...
-
Data Analysis
A repeated measures analysis of variance (ANOVA) statistical test was used to evaluate the effects of adding grab bars and a backrest to the station with regards to the maximum and minimum...
-
11B-604.4 Seats
The seat height of a water closet above the finish floor shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum measured to the top of the seat....
-
Completing the Checklist
If the measurement or number falls short of that required for accessibility, write the measurement or number to the right of the question in the area under “Comments.”...
-
11B-604.4 Seats
The seat height of a water closet above the finish floor shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum measured to the top of the seat....
-
11B-604.4 Seats
The seat height of a water closet above the finish floor shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum measured to the top of the seat....
-
1002.6.2 Transfer Height
The height of transfer device seats shall be 14 inches (355 mm) minimum and 24 inches (610 mm) maximum measured from the load and unload surface....
-
5.8.2.5 Toe Height
The toe height should be 18 inches minimum, measured above the ground when the top of the breast platform is 34 inches above the ground....
-
T402.8.2 Deployment to Boarding Platforms
The running slope of ramps and bridgeplates used for deployment to platforms shall be 1:8 maximum, as measured to the boarding platform with the non-rail vehicle resting on a flat surface...
-
2a
Do large showers measure at least 30" wide by 60" deep as shown in Figure 35(b) below?...