Transfer supports for transfer surfaces complying with M301.2.3.2 shall be 28 inches (710 mm) long minimum and shall be positioned along the width of transfer...
Search Results "Latch Side Clearance"
Commonly Searched Documents
- 
    
  
  M305.2.2.2 Side Transfer Supports
  
- 
    
  
  Transfer Surface (M301.2 and M302.2)
  The technical criteria in M301.2 and M302.2 address the height and size of the transfer surface, and the transfer sides.... 
- 
    
  
  213.2.1 Unisex (Single-Use or Family) Toilet and Unisex Bathing Rooms
  Doors to unisex toilet rooms and unisex bathing rooms shall have privacy latches.... 
- 
    
  
  604.5 Grab Bars
  Grab bars shall be provided on the side wall closest to the water closet and on the rear wall. Advisory 604.5 Grab Bars Exception 2.... 
- 
    
  
  11B-213.2.1 Unisex (single-user or family) toilet and unisex (single-user or family) bathing rooms
  Doors to unisex (single-user or family) toilet rooms and unisex bathing rooms shall have privacy latches.... 
- 
    
  
  11B-213.2.1 Unisex (single-user or family) toilet and unisex (single-user or family) bathing rooms
  Doors to unisex (single-user or family) toilet rooms and unisex bathing rooms shall have privacy latches.... 
- 
    
  
  R304.5.1.2 Shared Use Paths
  As proposed in the NPRM, R304.5.1 would require the clear width of curb ramp runs (excluding flared sides), blended transitions, and turning spaces to be 4 feet minimum.... 
- 
    
  
  11B-503.5 Vertical clearance
  spaces, access aisles serving them, and a vehicular route from an entrance to the passenger loading zone and from the passenger loading zone to a vehicular exit shall provide a vertical clearance... 
- 
    
  
  4.20.2 Floor Space
  Therefore, residential tubs that are only accessed from one open side, were typically designed with one end against a wall and 3 open sides from which assistance could be provided.... 
- 
    
  
  11B-604.8.1.5 Grab bars
  A side-wall grab bar complying with Section 11B-604.5.1 shall be provided and shall be located on the wall closest to the water closet.... 
- 
    
  
  11B-809.10.5.1 Clear floor space
  A clear floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be located with the long edge of the clear floor space parallel to the side of the bathtub or bathtub-shower... 
- 
    
  
  5.8.2.4 Unobstructed Floor Space Recommendation
  As was discussed above, the Committee considered anthropomorphic data that defined knee and toe clearances from a person’s abdomen.... 
- 
    
  
  Appendix 3 - Comparison of US Standards to IDEA Center Research
  Reach 1270 119 1597 1347 1704 Low Side Reach 380... 
- 
    
  
  11B-604.8.1.5 Grab bars
  A side-wall grab bar complying with Section 11B-604.5.1 shall be provided and shall be located on the wall closest to the water closet.... 
- 
    
  
  503.5 Vertical Clearance
  spaces, access aisles serving them, and a vehicular route from an entrance to the passenger loading zone, and from the passenger loading zone to a vehicular exit shall provide a vertical clearance... 
- 902.2 Baby Changing Table Knee Clearance
- 
    
  
  405.7.5 Doorways
  Where doorways are located adjacent to a ramp landing, maneuvering clearances required by 404.2.4 and 404.3.2 shall be permitted to overlap the required landing area.... 
- 
    
  
  405.7.5 Doorways
  Where doorways are located adjacent to a ramp landing, maneuvering clearances required by 404.2.4 and 404.3.2 shall be permitted to overlap the required landing area.... 
- 
    
  
  Grab Bar Cross Sections
  In addition, the minimum clearance between grab bars and protruding objects above has been changed from 15 inches to 12 inches (609.3), consistent with specifications for toilet paper dispensers... 
- 
    
  
  § 38.153(d)
  (d) The overhead clearance between the top of the lift door opening and the sill shall be the maximum practicable but not less than 65 inches (1651 mm).... 
- 
    
  
  405.7.5 Doorways
  Where doorways are located adjacent to a ramp landing, maneuvering clearances required by 404.2.4 and 404.3.2 shall be permitted to overlap the required landing area.... 
- 
    
  
  503.5 Vertical Clearance
  spaces, access aisles serving them, and a vehicular route from an entrance to the passenger loading zone, and from the passenger loading zone to a vehicular exit shall provide a vertical clearance... 
- 
    
  
  5.8.3 Breast Platform Recommendations
  5.8.3 Breast Platform Recommendations Description: In addition to providing knee and toe clearance at the breast platform (see 5.8.2 Knee and Toe Clearance Recommendations under Breast... 
- 
    
  
  Question 19
  the entrances to accessible public restrooms and fitting rooms free of obstacles that block the clear wall and floor space needed for opening the door (between 18 and 42 inches on the latch... 