EXCEPTION: Slopes not steeper than 1:48 shall be permitted. Advisory 304.2 Floor or Ground Surface Exception....
Search Results "Cross Slope"
Commonly Searched Documents
- 
    
  
  304.2 Floor or Ground Surfaces
  
 - 
    
  
  304.2 Floor or Ground Surfaces
  
EXCEPTION: Slopes not steeper than 1:48 shall be permitted. Advisory 304.2 Floor or Ground Surfaces Exception....
 - 
    
  
  11B-304.2 Floor or Ground Surfaces
  
Exception: Slopes not steeper than 1:48 shall be permitted. [2010 ADAS] Advisory 304.2 Floor or Ground Surfaces Exception. ...
 - 
    
  
  304.2 Floor or Ground Surfaces
  
[ECTCR UFAS 4.2.4.3] EXCEPTION: Slopes not steeper than 1:48 shall be permitted. Advisory 304.2 Floor or Ground Surfaces Exception....
 - 
    
  
  11B-304.2 Floor or Ground Surfaces
  
Exception: Slopes not steeper than 1:48 shall be permitted. [2010 ADAS] Advisory 304.2 Floor or Ground Surfaces Exception. ...
 - 
    
  
  11B-304.2 Floor or ground surfaces
  
Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted. Exception: Reserved. Advisory 11B-304.2 Floor or ground surface Exception....
 - 
    
  
  11B-406.5.10 Diagonal curb ramps
  
Diagonal curb ramps with flared sides shall have a segment of curb 24 inches (610 mm) long minimum located on each side of the curb ramp and within the marked crossing....
 - NYC Board of Elections: Video 6 - Verifying Temporary Solutions
 - 
    
  
  Q12: Full-depth Pavement Patching
  
If the pavement patching impacts the curb at a pedestrian street crossing where no curb ramp exists, the work affecting the curb falls within the definition of “alteration,” and a curb ramp...
 - 
    
  
  § 38.83(b)(8) Platform entrance ramp
  
The entrance ramp, or loading-edge barrier used as a ramp, shall not exceed a slope of 1:8 measured on level ground, for a maximum rise of 3 inches, and the transition from the station platform...
 - 
    
  
  Issue 3: Which signal? Speech WALK messages necessary
  
Pedestrians standing at one crosswalk could mistake the message of the other crosswalk for their indication to begin crossing....
 - 
    
  
  M305.2.4 Cross Section (Section-by-Section Analysis)
  
with non-circular cross sections to have a cross section dimension of 2 inches maximum, and a perimeter dimension of 4 inches minimum and 4.8 inches maximum....
 - 
    
  
  Attachment A: Violations Identified in the United States' Letter of Findings (Sept. 29, 2014)
  
[See subsections ...]
 - 
    
  
  Issue 4: Wrong pole! …Wrong message!
  
Since the APS is closer to the departure curb and curb ramp for crossing straight ahead (in line with the photographer’s direction of travel), a pedestrian hearing the sound from that APS...
 - 
    
  
  11B-705.1.1.3 Color and contrast
  
11B-705.1.1.3 Color and contrast. Detectable warning surfaces shall comply with Section 11B-705.1.1.3.1. The material used to comply with this section shall be an integral part of...
 - 
    
  
  11B-802.1.1 Floor or ground surface
  
Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted. Exception: Reserved....
 - AquaTrek2 ADA Wading Pool Ramp
 - 
    
  
  11B-502.4 Floor or ground surfaces
  
Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted. Exception: Reserved. Advisory 11B-502.4 Floor or ground surfaces....
 - 
    
  
  Tactile arrow
  
Tactile arrow The tactile arrow on the device must be aligned with the direction of travel on the crosswalk and point toward the street crossing that the pushbutton controls and signals...
 - 
    
  
  11B-406.5.1 Location
  
Curb ramps at marked crossings shall be wholly contained within the markings, excluding any flared sides. Exception: Diagonal curb ramps shall comply with Section 11B-406.5.9....
 - 
    
  
  11B-406.5.1 Location
  
Curb ramps at marked crossings shall be wholly contained within the markings, excluding any flared sides. Exception: Diagonal curb ramps shall comply with Section 11B-406.5.9....
 - 
    
  
  11B-406.5.1 Location
  
Curb ramps at marked crossings shall be wholly contained within the markings, excluding any flared sides. Exception: Diagonal curb ramps shall comply with Section 11B-406.5.9....
 - NewVision™ Curb Ramp Inventory System (NVCRIS)
 - 
    
  
  § 38.95(b)(8) Platform entrance ramp
  
The entrance ramp, or loading-edge barrier used as a ramp, shall not exceed a slope of 1:8, when measured on level ground, for a maximum rise of 3 inches, and the transition from station...
 
              