Learn more at http://medicalaccessibility.com/ Two Products in One - Combines a height-adjustable exam table with an accessible weight scale to save money and save space....
Search Results "Adult Changing Table"
- Stable and rock solid. See for yourself!
-
4(2)
(2) In single-story dwelling units, changes in level within the dwelling unit with heights between 1/4 inch and 1/2 inch are beveled with a slope no greater than 1:2....
-
11B-504.4 Tread surface
Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted. Exception: Reserved....
-
5.2.1 Transfer Surface Size Recommendations for M301
Depending on the configuration of the equipment, the transfer surface may occupy only a portion of an examination table or imaging bed platform....
-
M301.3 Supports (Section-by-Section Analysis)
An editorial change was made to this section as a result of the change in M301.3.2, described below, to replace the word “stirrups” with the term “leg supports.”...
-
Carpet [4.5.3]
The trim must meet requirements for changes in level....
-
M301.3.1 Transfer Supports (Section-by-Section Analysis)
The only change in the final rule was to update the cross reference to applicable transfer surfaces to accommodate the changes made to transfer surfaces, described above in Section IV.B.1...
-
M303.3 Entry
Where there is a change in level at the entry to wheelchair spaces, the change in level shall comply with M303.3....
-
M303.3 Entry
Where there is a change in level at the entry to a wheelchair space, the change in level shall comply with M303.3....
-
§ 38.125(c)(3) Ramp threshold
Changes in level between 1/4 inch and 1/2 inch shall be beveled with a slope no greater than 1:2....
-
11B-503.4 Floor and ground surfaces
Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted. Exception: Reserved....
-
11B-503.4 Floor and ground surfaces
Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted. Exception: Reserved....
-
§ 38.95(c)(3) Ramp threshold
Changes in level between 1/4 inch and 1/2 inch shall be beveled with a slope no greater than 1:2....
-
404.2.4.4 Floor or Ground Surface
Changes in level are not permitted. EXCEPTIONS: 1. Slopes not steeper than 1:48 shall be permitted. 2. Changes in level at thresholds complying with 404.2.5 shall be permitted....
-
404.2.4.4 Floor or Ground Surface
Changes in level are not permitted. EXCEPTIONS: 1. Slopes not steeper than 1:48 shall be permitted. 2....
-
404.2.4.4 Floor or Ground Surface
Changes in level are not permitted. EXCEPTIONS: 1. Slopes not steeper than 1:48 shall be permitted. 2. Changes in level at thresholds complying with 404.2.5 shall be permitted....
-
11B-404.2.4.4 Floor or ground surface
Changes in level are not permitted. Exceptions: 1. Slopes not steeper than 1:48 shall be permitted. 2. ...
-
11B-404.2.4.4 Floor or ground surface
Changes in level are not permitted. Exceptions: 1. Slopes not steeper than 1:48 shall be permitted. 2....
-
3. Getting Access to Medical Equipment
In a national survey of people with disabilities or activity limitations, wheelchair users reported the following: 69% had difficulty using exam tables; 60% had difficulty...
-
M301.2.3 Size (Section-by-Section Analysis)
As discussed in Section IV.B.1.c (Significant Changes – Transfer Surface Size), in the final rule the Access Board has revised this provision to account for the two types of transfer surfaces...
-
PEMKO 1-3/8" Floor Plates/Safety Treads Product No.195
Requires the Premium User plan or above. (Login or upgrade your account!)
-
PEMKO 4" Carpet Separator Threshold No. 2364
Requires the Premium User plan or above. (Login or upgrade your account!)
-
PEMKO 6" Carpet Separator Threshold No. 2366
Requires the Premium User plan or above. (Login or upgrade your account!)
-
PART 3: ACCESSIBLE EXAMINATION ROOMS
An accessible examination room has features that make it possible for patients with mobility disabilities, including those who use wheelchairs, to receive appropriate medical care....