Medical Diagnostic Equipment Advisory Committee MEDICAL DIAGNOSTIC EQUIPMENT ADVISORY COMMITTEE - Minority Report Regarding: 17 Inch Low Transfer Surface Height 09.27.13 These...
Search Results "Adjustable Height Counter"
Commonly Searched Documents
-
Medical Diagnostic Equipment Advisory Committee
-
9.2.2(7) Kitchens, Kitchenettes, or Wet Bars
Clear floor space for a front or parallel approach to cabinets, counters, sinks, and appliances shall be provided to comply with 4.2.4....
-
d. Unobstructed Transfer
This study examined the transfer experience with an adjustable height transfer surface. This study is available at http://herl.pitt.edu/ab/. ...
-
Chapter 1: Background
Current standards have criteria only related to seat height and clear floor space for wheelchair users (2)....
-
Clear Space Evaluation
However, when looking at Protocol A for the maximum height transfer only 65% of the population could transfer entirely inside of the 60 x 55.5 inch defined space....
-
4.9.2 Treads and Risers
On any given flight of stairs, all steps shall have uniform riser heights and uniform tread widths....
-
M301.2.3.1 End Transfer Surface
End transfer surfaces shall be 28 inches (710 mm) wide minimum and 17 inches (430 mm) long minimum. EXCEPTION: Transfer surfaces for imaging equipment with bores shall be...
-
M301.2.3.2 Side Transfer Surface
Side transfer surfaces shall be 28 inches (710 mm) wide minimum and 28 inches (710 mm) long minimum. EXCEPTION: Transfer surfaces for imaging equipment with bores shall be...
-
M301.2.4 Unobstructed Transfer
Each transfer surface shall provide two unobstructed sides for patient transfer. EXCEPTIONS: 1. Obstructions no more than 3 inches (75 mm) deep shall be permitted to extend beyond...
-
M301.4 Lift Compatibility
Diagnostic equipment shall be usable with portable patient lifts and, when in use with such lifts, shall comply with M301.4.1 or M301.4.2. EXCEPTION: Where fixed overhead patient...
-
M301.2.4 Unobstructed Transfer (Section-by-Section Analysis)
In the MDE NPRM the Access Board proposed that each transfer side provide unobstructed access to the transfer surface, with an exception to permit temporary obstructions as long as...
-
M301.4 Lift Compatibility
Diagnostic equipment shall be usable with a patient lift and shall comply with M301.4.1 or M301.4.2.
-
M301.2.3 Transfer Sides
The transfer surface shall be located to provide options to transfer from a mobility device onto one short side (depth) and one long side (width) of the surface. Each transfer side...
-
5.4.1 Transfer Support Location for M301 and M302
Rationale for the recommendation Transfer supports or handholds on adjustable medical equipment facilitate transfers onto a transfer surface by giving the individual something to hold...
- Murdock Manufacturing Waterless Campground Urinal, Front Mount
-
703.4 Installation Height and Location
703.4 Installation Height and Location. Signs with tactile characters shall comply with 703.4....
-
Study Objectives
Floor space needed for level, highest and lowest height transfers to seats without handhelds, with grab-bars, and with grab bars and a backrest d....
-
3.2 Getting on the Table
An accessible table is height adjustable to a minimum height of 17- 20 inches from the floor. ...
-
Adjustable height/gap protocol
Number of subjects that were able to attain a certain gap at a certain height under adjustable height/gap protocol Height\Gap 3.5" 7"...
-
703.4.1 Height above Finish Floor or Ground
703.4.1 Height above Finish Floor or Ground....
- IDeA Center: Transferring from Wheeled Mobility to MidMark's Barrier-Free Examining Table