End-of-Row Stalls The design of end-of-row stalls incorporates aisle space into the stall for easier maneuvering; consider this design even where a stall is not located at the end of...
Search Results "Access Aisle Width"
-
End-of-Row Stalls
-
Are accessible parking spaces required on a site where valet service is provided but vehicles are parked off site, such as in a public parking garage or on public streets?
Parking facilities with valet parking must provide accessible parking spaces to allow self-parking by people with disabilities (and must also provide an accessible passenger loading zone...
-
C.7.i. - Must Portable Document Format (PDF) files that are displayed on a Federal website meet the Access Board's standards?
Thus, the agency has two options when addressing PDF content and the Access Board's standards....
-
11B-1009.6.2 Handrails
The width between handrails shall be 20 inches (508 mm) minimum and 24 inches (610 mm) maximum....
-
Openings [§302.3]
Openings [§302.3] Openings in ground and floor surfaces, such as grates, are limited in width to prevent passage of a ½” diameter sphere....
-
11B-1009.6.2 Handrails
The width between handrails shall be 20 inches (508 mm) minimum and 24 inches (610 mm) maximum....
-
§ 38.153(b)
(b) All step edges shall have a band of color(s) running the full width of the step which contrasts from the step tread and riser, either dark-on-light or light-on-dark....
-
11B-1009.6.2 Handrails
The width between handrails shall be 20 inches (508 mm) minimum and 24 inches (610 mm) maximum....
-
1009.6.2 Handrails
The width between handrails shall be 20 inches (510 mm) minimum and 24 inches (610 mm) maximum. Handrail extensions required by 505.10.3 shall not be required on pool stairs....
-
11B-406.6 Islands
The clear width of the accessible route at islands shall be 60 inches (1524 mm) wide minimum. Where curb ramps are provided, they shall comply with Section 11B-406....
-
G.7.ii. - Are there any circumstances under which Federal EIT must be retrofitted with EIT that meets the access board's standards?
Section 508(a) generally requires that agencies ensure that the EIT they develop, procure, maintain, or use meets the Access Board's standards....
-
810.2.2 Dimensions
Bus stop boarding and alighting areas shall provide a clear length of 96 inches (2440 mm) minimum, measured perpendicular to the curb or vehicle roadway edge, and a clear width of 60 inches...
-
Stairs
Requirement: 4.9.4(2) If handrails are not continuous, they shall extend at least 12 in (305 mm) beyond the top riser and at least 12 in (305 mm) plus the width of one tread beyond the...
-
Side Entry: ADA Standard Section 1002.4.4.2
A 32 inch (815 mm) clear opening will not provide sufficient width when entered through a turn into an amusement ride....
-
11B-704.2.1.2 Forward approach
If an additional 6 inches (152 mm) in width of clear floor space is provided, creating a clear floor space of 36 inches by 48 inches (914 mm by 1219 mm), the enclosure may extend more than...
-
11B-1002.4.4.2 Side entry
A 32 inch (815 mm) clear opening will not provide sufficient width when entered through a turn into an amusement ride....
-
11B-704.2.1.2 Forward approach
If an additional 6 inches (152 mm) in width of clear floor space is provided, creating a clear floor space of 36 inches by 48 inches (914 mm by 1219 mm), the enclosure may extend more than...
-
11B-1002.4.4.2 Side entry
A 32 inch (815 mm) clear opening will not provide sufficient width when entered through a turn into an amusement ride....
-
603.2.3 Door Swing
Doors to a toilet room or bathing room for a single occupant accessed only through a private office and not for common use or public use shall be permitted to swing into the clear floor...
-
F216.13 Trailhead Signs
The technical requirements in 1017.11 require the signs to include information on the length of the trail or trail segment; surface type; typical and minimum tread width; typical and minimum...
-
603.2.3 Door Swing
Doors to a toilet room or bathing room for a single occupant accessed only through a private office and not for common use or public use shall be permitted to swing into the clear floor...
-
603.2.3 Door Swing
Doors to a toilet room or bathing room for a single occupant accessed only through a private office and not for common use or public use shall be permitted to swing into the clear floor...
-
Technical Requirements [1017]
The technical requirements for trails include specific provisions for the surface, clear tread width, passing spaces, tread obstacles, openings, running slope, cross slope, resting intervals...
-
1134A.6, Item 3
A clear maneuvering space at least 30 inches in width by 48 inches in length (762 mm by 1219 mm) shall be located outside the shower, flush and parallel to the control wall....