Delay in filing the complaint at the Federal level caused by pursuit of the remedies available under the grievance procedure would generally be considered good cause for extending the time...
Search Results "Extended Floor Surface"
Commonly Searched Documents
-
§35.107 Designation of Responsible Employee and Adoption of Grievance Procedures
-
24. Educational setting
As pointed out in several comments, the parents' right under §104.36 to challenge the placement of their child extends not only to placement in special classes or separate schools but also...
-
§35.107 Designation of responsible employee and adoption of grievance procedures (Section-by-Section Analysis)
Delay in filing the complaint at the Federal level caused by pursuit of the remedies available under the grievance procedure would generally be considered good cause for extending the time...
-
1003.3.1 Boat Slip Clearance
In existing piers, clear pier space shall be permitted to be located perpendicular to the boat slip and shall extend the width of the boat slip, where the facility has at least one boat...
-
III−1.1000 General
The obligations of title III only extend to private entities. State and local government entities are public entities covered by title II of the ADA, not by title III....
-
XI. Overview of Americans with Disabilities Act Accessibility Guidelines for New Construction and Alterations
Each floor in a building without a supervised sprinkler system must contain an "area of rescue assistance" (i.e., an area with direct access to an exit stairway where people unable to use...
-
C. Toilet Rooms:
PSE shall provide and maintain directional signage at inaccessible toilet rooms indicating the location of the nearest accessible toilet room on the Floor Level. ...
-
Accessible Route Into and Through the Business
clearance alongside the entrance door is blocked by a sale book rack, or if a route contains scattered trip hazards from impulse items displayed on cloth-covered tables or in baskets on the floor...
-
Accessible Routes Throughout the Museum
travel between stanchions or between a wall and a stanchion, passage must be maintained at a minimum of 36 inches wide, measured from inside edge to inside edge of the stanchion bases or floor...
- Pressalit Care VALUE Support Arm Fixed Height Swing Grab Bar with Leg
- Atlantis Railing
-
307.2 Protrusion Limits
Objects with leading edges more than 27 inches (685 mm) and not more than 80 inches (2030 mm) above the finish floor or ground shall protrude 4 inches (100 mm) maximum horizontally into...
-
11B-307.2 Protrusion limits
Objects with leading edges more than 27 inches (686 mm) and not more than 80 inches (2032 mm) above the finish floor or ground shall protrude 4 inches (102 mm) maximum horizontally into...
-
307.2 Protrusion Limits
Objects with leading edges more than 27 inches (685 mm) and not more than 80 inches (2030 mm) above the finish floor or ground shall protrude 4 inches (100 mm) maximum horizontally into...
-
Elevator Exemption
The 500 square foot maximum was based on a floor area allowance of 100 square feet per occupant, which is consistent with model building code requirements for business and industrial occupancies...
-
6. Where multiple swings in a swing bay are provided, Section 240.2.1.1 (one of each type) requires one swing to be located on an accessible route. If an accessible route is provided to more than one swing, can each swing be counted as an accessible ground level play component? If one is an infant seat and another a sling seat, are those considered two different types?
Swing bays that provide an accessible route, clear floor or ground space, maneuvering space, and the seat at a height between 11 to 24 inches to more than one swing, can count each swing...
-
703.4.2 Location
Signs containing tactile characters shall be located so that a clear floor space of 18 inches (455 mm) minimum by 18 inches (455 mm) minimum, centered on the tactile characters, is provided...
-
Addendum G: Comparison of Transfer Abilities between Men and Women
The average wheelchair seat to floor height for men was 22.2 (±1.44) inches and the average height for women was 21.65 (±1.31) inches....
-
A. Signs
If signs are provided for the following spaces, are the signs mounted on the wall (not the door) to the latch side of the door and centered 60" above the floor so that they can be easily...
-
Section 2. Definitions
New terms defined in the final Guidelines include: "adaptable," "assistive device," "ground floor," "loft," "multistory dwelling unit," "single-story dwelling unit," and "story"....
-
C. Accessibility Within Toilet Rooms
Is at least one stall at least 60 inches wide and 56 inches deep (wall mounted toilet) or 59 inches deep (floor mounted toilet)?...
-
407.12.2.1 Unobstructed Side Reach (Section-by-Section Analysis)
proposes that, where the operable part is located 10 inches or less behind the vertical reference plane, the operable part must be 48 inches high maximum and 15 inches high minimum above the floor...
-
What access do I need?
◼ I need an exam table that lowers to 17–19 inches from the floor. ◼ I need help getting on and off the exam table. ◼ I need to bring my service dog....
-
Tactile and Visual Signs [ADA Standards §216.2, §216.4.1]
This requirement applies to signs identifying stairways, floor levels, and areas of refuge. Examples of Signs Required to Meet Tactile and Visual Criteria...