Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device, or...
Search Results "Vertical Dispersion"
-
Structural Strength: ADA Standard Section 903.6
-
11B-610.4 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device, or...
-
11B-610.4 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device, or...
-
Wheelchair Spaces in Tiered Boxes
The proposed rule was not clear on how the scoping and dispersion requirements would apply in these types of facilities....
-
Structural Strength: ADA Standard Section 609.8
Section 609.8 covers the current ADA Standards for the structural strength of grab bars.
-
11B-407.4.10.3 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the support rail, fastener, mounting device...
-
11B-609.8 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the grab bar, fastener, mounting device,...
-
11B-609.8 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the grab bar, fastener, mounting device,...
-
11B-407.4.10.3 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the support rail, fastener, mounting device...
-
1015.2 Where required
shall be located along open-sided walking surfaces, including mezzanines, equipment platforms, aisles, stairs, ramps and landings, that are located more than 30 inches (762 mm) measured vertically...
-
PLATFORM (WHEELCHAIR) LIFT
mechanism equipped with a car or platform or support that serves two landings of a building or structure and is designed to carry a passenger or passengers and/or luggage or other material a vertical...
-
PLATFORM (WHEELCHAIR) LIFT
mechanism equipped with a car or platform or support that serves two landings of a building or structure and is designed to carry a passenger or passengers and/or luggage or other material a vertical...
-
11B-307.4.1 Guy braces
Where a guy support is used within either the width of a circulation path or 24 inches maximum outside of a circulation path, a vertical guy brace, sidewalk guy or similar device shall be...
-
11B-307.4.1 Guy braces
Where a guy support is used within either the width of a circulation path or 24 inches maximum outside of a circulation path, a vertical guy brace, sidewalk guy or similar device shall be...
-
Height: ADA Standard Section 505.4
Section 505.4 covers the current ADA Standards for the height of the top of the gripping surface of handrails.
-
11B-505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (864 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
11B-505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (864 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
- Reasonable Accommodation Management Software
-
Entrance
An entrance includes the approach walk, the vertical access leading to the entrance platform, the entrance platform itself, vestibule if provided, the entry door or gate, and the hardware...
-
232.2 General Holding Cells and General Housing Cells
Accessible cells or rooms should be dispersed among different levels of security, housing categories, and holding classifications (e.g., male/female and adult/juvenile) to facilitate access...
-
ENTRANCE
An entrance includes the approach walk, the vertical access leading to the entrance platform, the entrance platform itself, vestibule if provided, the entry door or gate, and the hardware...
-
11B.707.7.1.3 Horizontally mounted display screen
Where display screens are mounted tipped away from the viewer 60 degrees to 90 degrees (horizontal) from vertical, the center line of the display screen and other display devices shall be...
-
11B.707.7.1.3 Horizontally mounted display screen
Where display screens are mounted tipped away from the viewer 60 degrees to 90 degrees (horizontal) from vertical, the center line of the display screen and other display devices shall be...
-
11B.707.7.1.2 Angle-mounted display screen
Where display screens are mounted tipped away from the viewer 30 degrees to less than 60 degrees from vertical, the center line of the display screen and other display devices shall be no...