Search Results "Unobstructed Transfer"
Commonly Searched Documents
- Figure 1009.4.1 Clear Deck Space at Transfer Walls – Drawing from the U.S. Access Board
-
Chapter 4: Implications for standards and design
[See subsections ...]
-
1002.6.3 Wheelchair Storage Space
Wheelchair storage spaces complying with 305 shall be provided in or adjacent to unload areas for each required transfer device and shall not overlap any required means of egress or accessible...
-
1002.6.3 Wheelchair Storage Space
Wheelchair storage spaces complying with 305 shall be provided in or adjacent to unload areas for each required transfer device and shall not overlap any required means of egress or accessible...
- Willoughby Industries ADA Cabinet Shower US-FA-HC
- Willoughby Industries US-HC Cabinet Shower
-
1008.4.2 Clear Floor or Ground Space
Where play components include a seat or entry point, designs that provide for an unobstructed transfer from a wheelchair or other mobility device are recommended....
-
1008.4.2 Clear Floor or Ground Space
Where play components include a seat or entry point, designs that provide for an unobstructed transfer from a wheelchair or other mobility device are recommended....
-
Requirement 5. Light switches, electrical outlets, thermostats and other environmental controls in accessible locations.
Section 100.205(c)(3)(ii) requires that all covered multifamily dwellings with a building entrance on an accessible route shall be designed and constructed in such a manner that all...
-
M301.2.2 Sunset
The low transfer position height, Item A of M301.2.1, shall cease to have effect on [Insert date 5 years after date of publication in the Federal Register]....
-
Exercise Machines and Equipment
Section 1004.1 of the 2010 Standards requires a clear floor space “positioned for transfer or for use by an individual seated in a wheelchair” to serve at least one of each type of exercise...
-
1c
c. Is there a 36" wide by 48" long clear floor space directly outside the shower for persons who use wheelchairs to approach and use the shower as shown in Figure 35(a) above? [ADA...
-
5.1.5 Floor Height
Where the floor at the entrance to the camp shelter is elevated above the ground surface, the floor shall be 17 (430 mm) high minimum to 19 inches (485 mm) high maximum measured from...
-
A4.21.1 GENERAL
Shower stalls that are 36 in by 36 in (915 mm by 915 mm) wide provide additional safety to people who have difficulty maintaining balance because all grab bars and walls are within...
-
5.1.5 Floor Height
Where the floor at the entrance to the camp shelter is elevated above the ground surface, the floor shall be 17 (430 mm) high minimum to 19 inches (485 mm) high maximum measured from...
-
4.21.2 Size and Clearances
4.21.2 Size and Clearances. Minimum guidelines for roll-in shower stalls are based on residential size fixtures (30" x 60" minimum or the space used by a standard residential...
-
Clear Floor Space
Clear Floor Space The load and unload areas adjacent to ride seats designed for transfer must have a clear space of 30 by 48 inches minimum....
-
1. Transfer Surface
[See subsections ...]
- Access-Able Designs Shower Transfer Bench SH-400-2SDL
-
5.4.3 Transfer Support Height for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.3 Transfer Support Height for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
-
11B-809.10.6.1 Size
When one or more shower stalls are provided within the same dwelling unit, as least one shower stall shall comply with one of the following: A transfer type shower compartment...
-
5.2.1.4 Transfer Surface Size Recommendations for Imaging Equipment (M301)
When patients transfer on the long side, table depth may be equal to the transfer surface depth....
-
2. What does the ADA require for accessibility of pools?
One means of entry/exit must be a fixed pool lift or sloped entry; the other entry can be a transfer wall, transfer system, or pool stairs....
- Access-Able Designs Wall Mounted Shower Transfer Bench SH-400