[See subsections ...]
Search Results "Pocket Door"
Commonly Searched Documents
-
2016 California Standards for Accessible Design
-
2019 California Standards for Accessible Design Guide (effective January 1, 2020)
Including selected excerpts from the Americans with Disabilities Act and Safe Harbor criteria Effective January 1, 2020 Version 1.0 COMPILED and © 2019 by EVAN TERRY...
-
11B-604.8.1.1.1 Maneuvering space with in-swinging door
In a wheelchair accessible compartment with an in-swinging door, a minimum 60 inches (1524 mm) wide by 36 inches (914 mm) deep maneuvering space shall be provided in front of the clearance...
-
11B-604.8.1.1.1 Maneuvering space with in-swinging door
In a wheelchair accessible compartment with an in-swinging door, a minimum 60 inches (1524 mm) wide by 36 inches (914 mm) deep maneuvering space shall be provided in front of the clearance...
- LaCantina Doors
-
SECTION 1010 DOORS, GATES AND TURNSTILES
[DSA-AC] In addition to the requirements of this section, means of egress, which provide access to, or egress from, buildings or facilities where accessibility is required for...
-
SECTION 1010 DOORS, GATES AND TURNSTILES
[DSA-AC] In addition to the requirements of this section, means of egress, which provide access to, or egress from, buildings or facilities where accessibility is required for...
-
19.1 Q. If a sliding door track has a threshold of 3/4, does this trigger requirements for ramps?
The Guidelines at Requirement 4 provide that thresholds at doors, including sliding door tracks, may be no higher than 3/4 and must be beveled with a slope no greater than 1:2....
-
H3
[ADA Standards § 4.13.9] Yes No If No, can the door be propped open without compromising privacy, or can the hardware be modified by adding new accessible hardware, or adapting...
-
Elevator Door Requirements [§407.3]
Elevator Door Requirements [§407.3]...
-
4.8.4(4)
(4) If a doorway is located at a landing, then the area in front of the doorway shall comply with 4.13.6.
-
Controls [§404.3.5]
Controls [§404.3.5] Door and gate controls must be compliant as operable parts (operable with one hand and without tight grasping, pinching, twisting of the wrist, or more than 5 lbf)...
-
Re: 404.2.4.3 Recessed Doors and Gates
Notice that the text does not match the figure for a push approach door. This may be an error in the Standards, but since the text governs, it exceeds the illustrated requirement. ...
-
4.10.9 Floor Plan of Elevator Cars
Acceptable door opening and inside dimensions shall be as shown in Fig. 22....
-
4.10.9 FLOOR PLAN OF ELEVATOR CARS
Acceptable door opening and inside dimensions shall be as shown in Fig. 22....
-
Door Swing [§304.4] and Other Space Requirements
Door Swing [§304.4] and Other Space Requirements Doors can swing into the turning space....
-
Multiple Usable Entrances
However, the requirements for usable doors and an accessible route to exterior spaces such as balconies and decks does respond to this concern....
-
11B-411.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....
-
11B-411.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....
-
11B-411.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....
- Norton Surface Mounted 5600 Hands-Free Door Operation Kits
- Access Board: Door Opening Force
-
Error/Omission: The door to the toilet room swings into the required clear floor space at accessible fixtures, controls, and dispensers.
Error/Omission: The door to the toilet room swings into the required clear floor space at accessible fixtures, controls, and dispensers....