The rise for any ramp run connecting elevated play components shall be 12 inches (305 mm) maximum....
Search Results "Elevator Hall Signal"
Commonly Searched Documents
-
1008.2.5.2 Elevated
-
1008.2.5.2 Elevated
The rise for any ramp run connecting elevated play components shall be 12 inches (305 mm) maximum....
-
11B-411.2.1.3.2 Touch screen call console arrangement
Where touch screen call consoles are provided, the touch screen shall be located directly above the accessibility function button. The accessibility function button shall be located...
-
11B-411.2.1.3.2 Touch screen call console arrangement
Where touch screen call consoles are provided, the touch screen shall be located directly above the accessibility function button. The accessibility function button shall be located...
-
11B-411.2.1.3.2 Touch screen call console arrangement
Where touch screen call consoles are provided, the touch screen shall be located directly above the accessibility function button. The accessibility function button shall be located...
-
409.4.1 Inside Dimensions of Elevator Cars
409.4.1 Inside Dimensions of Elevator Cars. Elevator cars shall provide a clear floor space of 36 inches (915 mm) minimum by 48 inches (1220 mm) minimum and shall comply with 305....
-
Can elevator doors close sooner than the minimum opening time specified when users activate door close?
User activation of door close (or automatic operation) cannot reduce the initial opening time of doors (3 seconds minimum) or the minimum door signal timing (based on 1.5/ ft/s travel speed...
-
Savaria ORION Limited Use/Limited Application Elevator
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Elevated Play Component
A play component that is approached above or below grade and that is part of a composite play structure consisting of two or more play components attached or functionally linked to...
-
ELEVATED PLAY COMPONENT
[DSA-AC] A play component that is approached above or below grade and that is part of a composite play structure consisting of two or more play components attached or functionally...
-
ELEVATED PLAY COMPONENT
[DSA-AC] A play component that is approached above or below grade and that is part of a composite play structure consisting of two or more play components attached or functionally...
-
11B-409 PRIVATE RESIDENCE ELEVATORS
[See subsections ...]
-
11B-411 Destination-oriented elevators
[See subsections ...]
-
11B-409 Private residence elevators
[See subsections ...]
-
11B-411 Destination-oriented elevators
[See subsections ...]
-
11B-409 Private residence elevators
[See subsections ...]
-
407.2.2.4 Differentiation
Each destination-oriented elevator in a bank of elevators shall have audible and visible means for differentiation....
-
407.2.2.4 Differentiation
Each destination-oriented elevator in a bank of elevators shall have audible and visible means for differentiation....
-
407.2.2.4 Differentiation
Each destination-oriented elevator in a bank of elevators shall have audible and visible means for differentiation....
-
11B-408.3.2.1 Power operation
Swinging doors shall be power-operated and shall comply with ANSI/BHMA A156.19.
-
11B-408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated.
-
409.3 Elevator Doors
Hoistway doors, car doors, and car gates shall comply with 409.3 and 404. EXCEPTION: Doors shall not be required to comply with the maneuvering clearance requirements in 404.2.4.1...
-
409.3 Elevator Doors
Hoistway doors, car doors, and car gates shall comply with 409.3 and 404. EXCEPTION: Doors shall not be required to comply with the maneuvering clearance requirements in 404.2.4.1...
-
11B-411.1.1 Floor designations
In facilities served by destination-oriented elevator systems, floor designations shall be numeric characters only....