It is not required by this code to provide an accessible route when the terrain of the site is such that both of the following apply: 1. The slopes of the undisturbed site...
Search Results "Elevator Building"
-
11B-233.3.1.2.6.2 Test number one, individual building test
-
11B-233.3.1.2.6.2 Test number one, individual building test
It is not required by this code to provide an accessible route when the terrain of the site is such that both of the following apply: 1. The slopes of the undisturbed site...
-
1009.4 Elevators
, Title 8, Division 1, Chapter 4, Subchapter 6, Elevator Safety Orders....
-
III-7.3120 Temporary structures
Temporary buildings that are extensively used or are essential for public use are covered....
-
11B-216.7 Elevators
Existing buildings that have been remodeled to provide specific elevators for public use that comply with these building standards shall have the location of and the directions to these...
-
11B-216.7 Elevators
Existing buildings that have been remodeled to provide specific elevators for public use that comply with these building standards shall have the location of and the directions to these...
-
11B-216.7 Elevators
Existing buildings that have been remodeled to provide specific elevators for public use that comply with these building standards shall have the location of and the directions to these...
-
11B-240.2.2 Elevated play components
Where elevated play components are provided, at least 50 percent shall be on an accessible route and shall comply with Section 11B-1008.4....
-
11B-240.2.2 Elevated play components
Where elevated play components are provided, at least 50 percent shall be on an accessible route and shall comply with Section 11B-1008.4....
-
1007.4 Elevators
1007.4 Elevators. ...
-
11B-240.2.2 Elevated play components
Where elevated play components are provided, at least 50 percent shall be on an accessible route and shall comply with Section 11B-1008.4....
-
Can audible signals for an elevator operate only when needed by a passenger who needs them through activation of dedicated “accessibility” control?
No, audible (and visible) signals required for elevators must function automatically at all times an elevator is operational....
-
General: ADA Standard Section 409.1
Section 409.1 of the ADA Standards covers information in the current ADA Standards for private residence elevators.
-
12204(c)(3) Other sites
.-- With respect to alterations of buildings or facilities designated as historic under State or local law, the guidelines described in paragraph (1) shall establish procedures equivalent...
-
12204(c)(3) Other sites
(3) Other sites With respect to alterations of buildings or facilities designated as historic under State or local law, the guidelines described in paragraph (1) shall establish procedures...
-
68.20(d) Public Accommodations
(d) The following private buildings and facilities constructed, renovated, or modified on or after January 1, 1992 and defined as a "public accommodation" by Section 301, Americans with...
-
407.4.7 Designations and Indicators of Car Controls
EXCEPTION: In existing elevators, where a new car operating panel complying with 407.4.7 is provided, existing car operating panels shall not be required to comply with 407.4.7....
-
407.4.7 Designations and Indicators of Car Controls
EXCEPTION: In existing elevators, where a new car operating panel complying with 407.4.7 is provided, existing car operating panels shall not be required to comply with 407.4.7....
-
1009.4.1 Standby power
The elevator shall meet the emergency operation and signaling device requirements of California Code of Regulations, Title 8, Division 1, Chapter 4, Subchapter 6, Elevator Safety Orders....
-
11B-407.4.10.3 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the support rail, fastener, mounting...
-
11B-407.4.10.1 Location
Clearance between support rails and adjacent surfaces shall be 1½ inches (38 mm) minimum. Top of support rails shall be 31 inches (787 mm) minimum to 33 inches (838 mm) maximum above...
-
11B-407.4.10.2 Surfaces
Support rails shall be smooth and any surface adjacent to them shall be free of sharp or abrasive elements.
-
11B-411.4.6.1 Location
Controls shall be located within one of the reach ranges specified in Section 11B-308.
-
11B-411.2.3.2 Car designation signs
Car designation signs complying with Sections 11B-703.2 and 11B-703.4.1 shall be provided on both jambs of the hoistway immediately below the floor designation. Signs shall be...