These guidelines cover temporary buildings or facilities as well as permanent facilities....
Search Results "Elevator Building"
-
4.1.1(4) Temporary Structures
-
11B-407.4.6.2 Buttons
[2010 ADA Standards] EXCEPTION: In existing elevators, buttons shall be permitted to be recessed....
-
11B-407.4.6.2 Buttons
[2010 ADA Standards] EXCEPTION: In existing elevators, buttons shall be permitted to be recessed....
-
1.1.9 Effective date of this code
Only those standards approved by the California Building Standards Commission that are effective at the time an application for building permit is submitted shall apply to the plans and...
-
11B-407.4.8.1 Visible indicators
Visible indicators shall comply with Section 11B-407.4.8.1.
-
11B-411.3.4 Door delay
Door delay shall comply with Section 11B-407.3.5.
-
11B-411.3.4 Door delay
Door delay shall comply with Section 11B-407.3.5.
-
11B-407.4.8.1 Visible indicators
Visible indicators shall comply with Section 11B-407.4.8.1.
-
1008.2.4.2 Elevated
1008.2.4.2 Elevated. The clear width of accessible routes connecting elevated play components shall be 36 inches (915 mm) minimum. EXCEPTIONS: 1....
-
Exception 9
In alteration projects involving buildings and facilities previously approved and built without elevators, areas above and below the ground floor are subject to the 20-percent disproportionality...
-
Elevator Landing Requirements [§407.2]
Elevator Landing Requirements [§407.2]...
-
Symmetry Elevating Solutions Limited Use/Limited Application (LU/LA) Elevator
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Clear Floor or Ground Space: ADA Standard Section 407.2.1.3
Section 407.2.1.3 covers the current ADA Standards for the clear floor or ground space at elevator call controls.
-
Areas of Refuge: ADA Standard Section 216.4.2
Section 216.4.2 covers scoping requirements in the current ADA Standards for signs at areas of refuge.
-
11B-411.2.1.6 Identification of floors served
In buildings with two or more elevator banks, each serving a different group of specific floors, hall call consoles located on floors with a building entry, including parking and transfer...
-
11B-411.2.1.6 Identification of floors served
In buildings with two or more elevator banks, each serving a different group of specific floors, hall call consoles located on floors with a building entry, including parking and transfer...
-
407.3 Elevator Door Requirements
407.3 Elevator Door Requirements. Hoistway and car doors shall comply with 407.3....
-
Lifts and Elevators
If the voting area is not on the same level as the entrance, there must be an independently operable elevator or lift to provide an accessible route to individuals with disabilities....
-
1008.2.4.2 Elevated
The clear width of accessible routes connecting elevated play components shall be 36 inches (915 mm) minimum. EXCEPTIONS: 1....
-
1008.2.4.2 Elevated
The clear width of accessible routes connecting elevated play components shall be 36 inches (915 mm) minimum. EXCEPTIONS: 1....
-
11B-233.3.1.2.6.2 Test number one, individual building test
It is not required by this code to provide an accessible route when the terrain of the site is such that both of the following apply: 1. The slopes of the undisturbed site...
-
11B-233.3.1.2.6.2 Test number one, individual building test
It is not required by this code to provide an accessible route when the terrain of the site is such that both of the following apply: 1. The slopes of the undisturbed site...
-
III-7.3120 Temporary structures
Temporary buildings that are extensively used or are essential for public use are covered....
-
Platform to Hoistway Clearance: ADA Standard Section 407.4.3
Section 407.4.3 covers the current ADA Standards for the required clearance between the elevator car platform and the hoistway landing.