Notice that the text does not match the figure for a push approach door. This may be an error in the Standards, but since the text governs, it exceeds the illustrated requirement. ...
Search Results "Clearance in Base"
-
Re: 404.2.4.3 Recessed Doors and Gates
-
11B-404.2.4.2 Doorways without doors or gates, sliding doors, and folding doors
Doorways less than 36 inches (914 mm) wide without doors or gates, sliding doors, or folding doors shall have maneuvering clearances complying with Table 11B-404.2.4.2....
-
1133A.7 Knee and toe space
1133A.7 Knee and toe space. Knee and toe space, when required by Section 1133A, shall comply with the following:
-
1133A.7, Item 2
2. The knee and toe space shall be 30 inches (762 mm) wide minimum, centered on the sink, countertop or appliance.
-
4.26.2* SIZE AND SPACING OF GRAB BARS AND HANDRAILS
The diameter or width of the gripping surfaces of a handrail or grab bar shall be 1-1/4 in to 1-1/2 in (32 mm to 38 mm), or the shape shall provide an equivalent gripping surface. If...
-
4.26.2* Size and Spacing of Grab Bars and Handrails
The diameter or width of the gripping surfaces of a handrail or grab bar shall be 1‒1/4 in to 1‒1/2 in (32 mm to 38 mm), or the shape shall provide an equivalent gripping surface. If...
-
1133A.7 Knee and toe space
Knee and toe space, when required by Section 1133A, shall comply with Section 1138A.2 and the following:
-
1133A.7, Item 2
2. The knee and toe space shall be 30 inches (762 mm) wide minimum, centered on the sink, countertop or appliance.
-
11B-809.8.3 Door maneuvering clearance.
At the dwelling unit side of the primary entry doors, secondary exterior doors, and required exit doors maneuvering clearances shall be 44 inches (1118 mm) minimum in length measured...
-
404.2.4.2 Doorways without Doors or Gates
Doorways less than 36 inches (915 mm) wide without doors or gates, sliding doors, or folding doors shall have maneuvering clearances complying with Table 404.2.4.2....
-
404.2.4.2 Doorways without Doors or Gates
Doorways less than 36 inches (915 mm) wide without doors or gates, sliding doors, or folding doors shall have maneuvering clearances complying with Table 404.2.4.2....
-
Error/Omission: No van accessible spaces are provided in the parking area.
The vertical clearance at such spaces shall comply with 4.6.5. All such spaces may be grouped on one level of a parking structure....
- Web Accessibility Issues: Experiences of Students with Disabilities
- Quadraplegic Transfer
- SafePath: ADA Door Access - What is a Level Landing?
-
How to do a Bed Transfer
Requires the Registered User plan or above. Login!
-
Transfer Demonstration from Wheelchair to Bed and Back to Wheelchair
Requires the Registered User plan or above. Login!
-
11B-404.2.4.2 Doorways without doors or gates, sliding doors, and folding doors
Doorways less than 36 inches (914 mm) wide without doors or gates, sliding doors, or folding doors shall have maneuvering clearances complying with Table 11B-404.2.4.2....
-
11B-404.2.4.2 Doorways without doors or gates, sliding doors, and folding doors
Doorways less than 36 inches (914 mm) wide without doors or gates, sliding doors, or folding doors shall have maneuvering clearances complying with Table 11B-404.2.4.2....
-
404.2.4.2 Doorways without Doors or Gates, Sliding Doors, and Folding Doors
Doorways less than 36 inches (915 mm) wide without doors or gates, sliding doors, or folding doors shall have maneuvering clearances complying with Table 404.2.4.2....
-
Standard Stall
Except for end-of-row stalls, doors must swing out due to the confined space within stalls (less clearance is required on the push side of doors)....
-
Beds: ADA Standard Section 224.3