Where writing desks or tables are provided, a minimum of at least one writing desk or table that complies with 4.32 must be provided....
Search Results "Adult Changing Table"
-
9.2* POST OFFICE LOBBIES
- UpScale by Medical Accessibility - Adjustable Height Exam Table with Built-in Scale
-
Additional Transfer Techniques: Use of Stretchers and Gurneys
Other equipment may be located in spaces with no room at the end of the table making it impossible to position a portable floor lift....
-
Summary of Recommendations
Summary of Recommendations
-
§ 35.151(b)(4)(ii)(C) Safe harbor
with the specifications in either the 1991 Standards or the Uniform Federal Accessibility Standards, the public entity is not required to retrofit such elements to reflect incremental changes...
-
4.1.5 Slope
The slope of the surface of the clear floor or ground space around a picnic table shall not exceed 1:48 (2 percent) in any direction. Exception....
-
§ 35.151(b)(4)(ii)(C) Safe harbor
specifications in either the 1991 Standards or the Uniform Federal Accessibility Standards before March 15, 2012, the public entity is not required to retrofit such elements to reflect incremental changes...
- PEMKO 1 3/8" Carpet Separator Threshold No. 1951
- PEMKO 1 3/4" Carpet Separator Threshold No. 236
- PEMKO 2 1/2" Carpet Separator Threshold No. 174
-
Transfer Surface Size – M301.2.2 Supine, Prone, or Side-Lying Position
Transfer Surface Size – M301.2.2 Supine, Prone, or Side-Lying Position The issues were discussed and decided in the full committee meeting as follows: depth of 17 inches minimum...
-
4.1.3 Adjustable Height Chairs with and without Footplates
, reducing the distance between the floor and seat height may also restrict the overall length of the table when the patient is reclined into a supine position....
-
304.2 Floor or Ground Surfaces
Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted. Advisory 304.2 Floor or Ground Surface Exception....
-
304.2 Floor or Ground Surfaces
Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted. Advisory 304.2 Floor or Ground Surfaces Exception....
-
11B-304.2 Floor or Ground Surfaces
Changes in level are not permitted. Exception: Slopes not steeper than 1:48 shall be permitted. [2010 ADAS] Advisory 304.2 Floor or Ground Surfaces Exception. ...
-
304.2 Floor or Ground Surfaces
Changes in level are not permitted. [ECTCR UFAS 4.2.4.3] EXCEPTION: Slopes not steeper than 1:48 shall be permitted. Advisory 304.2 Floor or Ground Surfaces Exception....
-
11B-304.2 Floor or Ground Surfaces
Changes in level are not permitted. Exception: Slopes not steeper than 1:48 shall be permitted. [2010 ADAS] Advisory 304.2 Floor or Ground Surfaces Exception. ...
-
11B-304.2 Floor or ground surfaces
Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted. Exception: Reserved. Advisory 11B-304.2 Floor or ground surface Exception....
-
1018.5 Obstacles
Obstacles on beach access routes and resting intervals shall not exceed 1/2 inch (13 mm) in height measured vertically to the highest point. EXCEPTION: Where the surface is other...
-
1018.5 Obstacles
Obstacles on beach access routes and resting intervals shall not exceed 1/2 inch (13 mm) in height measured vertically to the highest point. EXCEPTION: Where the surface is other...
-
M305.5 Head and Back Support (Section-by-Section Analysis)
One manufacturer asserted that this requirement was ambiguous and that he had to read it multiple times to understand it; however, this commenter also indicated that the tables it currently...
-
3) Where the standard says "Changes in level are not permitted", but no advisory follows the standard
3) Where the standard says "Changes in level are not permitted", but no advisory follows the standard, such as 404.2.4.4 floor or ground surfaces at doors: Although the Advisory at 304.2...
- GameTime Spiral Game Table
-
5.2.1.1 Transfer Surface Width Recommendations for M301
As part of the deliberations, Committee members examined tables and chairs from various manufacturers during its meetings....