One fixed showerhead shall be 48 inches (1220 mm) above the floor or ground surface, and one fixed shower head shall be 72 inches (1830 mm) minimum above the floor or ground surface....
Search Results "Lavatory Clear Floor Space"
-
4.8.1 General
-
Extensions
Extensions must be rounded or returned to the walls, floors, or posts....
-
205 Operable Parts
The guidelines require operable parts on accessible routes and in accessible rooms and spaces to be accessible....
-
Standard Roll-In Type Shower Compartments: ADA Standard Section 608.5.2
Section 608.5.2 covers the current ADA Standards for controls in standard roll-in type shower compartments.
-
907.4.2.2 Height
The height of the manual fire alarm boxes shall be not less than 42 inches (1067 mm) and not more than 48 inches (1219 mm) measured vertically, from the floor level to the highest point...
-
11B-209.2.1 Passenger drop-off and loading zones
and 11B-209.2.3, shall provide at least one passenger drop-off and loading zone complying with Section 11B-503 in every continuous 100 linear feet (30480 mm) of drop-off and loading zone space...
-
SELF-SERVICE STORAGE
[DSA-AC] Building or facility designed and used for the purpose of renting or leasing individual storage spaces to customers for the purpose of storing and removing personal property on...
-
1133A.2.1, Item 1
U-shaped kitchens, designed with parallel approach at a range or cooktop located at the base of the U, shall have a minimum clear width of at least 60 inches (1524 mm)....
-
11B-608.5.2 Standard roll-in type shower compartments
seat wall 19 inches (483 mm) minimum and 27 inches (686 mm) maximum from the seat wall; and shall be located above the grab bar, but no higher than 48 inches (1219 mm) above the shower floor...
-
ADDITION
An expansion, extension, or increase in the gross floor area of a building or facility....
-
216.5 Parking
Parking spaces complying with 502 shall be identified by signs complying with 502.6. EXCEPTIONS: 1....
-
11B-407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (889 mm) minimum above the finish floor....
-
Surface and Slope [1012.4 and 1012.5]
The surface of parking spaces and pull-up spaces for RVs must be firm and stable....
-
Sec.36.401(d)(3)
For example, in a facility that houses a shopping center or shopping mall, or a professional office of a health care provider, the floors that are above or below an accessible ground floor...
-
§ 36.401(d)(3)
For example, in a facility that houses a shopping center or shopping mall, or a professional office of a health care provider, the floors that are above or below an accessible ground floor...
-
11B-608.6 Shower spray unit and water
One shower head shall be located at a height of 48 inches (1219 mm) maximum above the shower finish floor....
-
Paperwork Reduction Act
The Paperwork Reduction Act of 1980 (PRA) requires agencies to clear forms and recordkeeping requirements with OMB before they can be introduced. 44 U.S.C. 3501 et seq....
-
ADAAG
Warnings (suspension of the requirement as it applies to curb ramps, hazardous vehicular areas, and reflecting pools) and 4.34 Automated Teller Machines (revision of specifications for clear...
-
Drinking Fountains
Requirement: 4.1.3(10)* Drinking Fountains: (a) Where only one drinking fountain is provided on a floor there shall be a drinking fountain which is accessible to individuals who use...
-
11B-809.10.5.2 Reinforcement for grab bars
Where bathtubs are installed without surrounding walls reinforcement shall be provided for floor-mounted grab bars. 2....
-
11B-502.6.3 Location
A parking space identification sign shall be visible from each parking space....
-
IDEA Center
Analysis of individual participants with very large measurements for length identified two clear “outliers” who were excluded from the sample....
-
1009.6.1 Travel distance
The maximum travel distance from any accessible space to an area of refuge shall not exceed the exit access travel distance permitted for the occupancy in accordance with Section 1017.1....