guideline addresses planning and design of a building and site, including all features used to access the building or facility, such as walkways and pathways, stairs, and ramps; interior spaces...
Search Results "Shower Clear Floor Space"
Commonly Searched Documents
- Design Guidelines for the Visual Environment
- Association for Macular Diseases
- DO-IT Center
- Tactile Design for Universal Access
-
1009.10 Directional signage
indicating the location of the other means of egress and which of those are accessible means of egress shall be provided at the following: At exits serving a required accessible space...
- Accessible Icon Project
-
Do the surface requirements, including those for maximum slope (1:48), apply to all portions of a parking lot?
No, the surface criteria apply only to accessible parking spaces, access aisles, and accessible routes, including those serving other elements or spaces besides parking spaces....
-
HALL CALL CONSOLE
[DSA-AC] An elevator call user interface exclusive to a destination-oriented elevator system that requires the user to select a destination floor prior to entering the elevator car....
-
f-v
Are the controls and operating mechanisms mounted no more than 54 inches above the floor for a side reach or 48 inches for a forward reach?...
-
3. Bank of House Phones
If one house phone or one bank of house phones is provided on a given floor, does at least one house phone have the following features: [ADA Stds. 4.1.3(17)]...
-
K5
If the operating controls are set back 10 to 24 inches from the front edge of the counter or table are they no higher than 46 inches above the floor?...
-
407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (125 mm) nominal and 29 inches (735 mm) nominal above the finish floor....
-
1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (280 mm) minimum and 18 inches (455 mm) maximum measured to the top of the surface from the ground or floor surface....
-
A4.23.9 Medicine Cabinets
Shelves, drawers, and floor-mounted cabinets can be provided within the reach ranges of disabled people....
-
4.15.2* SPOUT HEIGHT
Spouts shall be no higher than 36 in (915 mm), measured from the floor or ground surfaces to the spout outlet (see Fig. 27(a))....
-
4.34.6.5(5)
The finished flooring shall extend under the counter to the wall....
-
A4.23.9 MEDICINE CABINETS
Shelves, drawers, and floor-mounted cabinets can be provided within the reach ranges of disabled people....
-
M303.4.1 Breast Platforms
The height of the breast platform shall be 30 inches (760 mm) high minimum and 42 inches (1065 mm) high maximum above the floor when in use by a patient seated in a wheelchair....
-
Handrail Extensions [§505.10]
Handrail Extensions [§505.10] Handrail extensions at the top and bottom must return to walls, guards, or floors and horizontal portions must comply as protruding objects....
-
11B-813.2.6 Shelf
No fewer than one shelf shall be provided in close proximity to the changing table at 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor....
-
Alterations [§202.3]
Similarly, where spaces are altered, the standards apply to those spaces that are altered....
-
A. Self Parking
" spaces for those who use lift-equipped vans?...
-
11B-225.3 Self-service storage facilities
Self-service storage facilities shall provide individual self-service storage spaces complying with these requirements in accordance with Table 11B-225.3....
-
3.7 Louisville Tinseltown 19, 4400 Towne Center Drive, Louisville, Kentucky
- In Auditorium 10, the four (4) wheelchair spaces shall be relocated one row farther back in the auditorium from their current location....