be at least 36 inches wide, have no abrupt vertical changes in level (such as a step), have a running slope no more than 1:12 in most cases, and meet other requirements for cross slope, surface...
Search Results "Hybrid Surface System"
-
B) Accessible Route
-
Parking Spaces [4.6.3]
A maximum slope of 2% is required in all directions for both the space and access aisle since level surfaces are important for wheelchair transfer to and from vehicles....
-
308.3.2 Obstructed High Reach
Operable parts of fuel dispensers shall be permitted to be 54 inches (1370 mm) maximum measured from the surface of the vehicular way where fuel dispensers are installed on existing curbs...
-
308.3.2 Obstructed High Reach
Operable parts of fuel dispensers shall be permitted to be 54 inches (1370 mm) maximum measured from the surface of the vehicular way where fuel dispensers are installed on existing curbs...
-
Location [§208.3]
Locating accessible spaces required for a parking structure in a surface lot often will not qualify for this exception because such a location typically offers less convenience, security...
-
Slope [§405.2] and Cross Slope [§405.3]
will accommodate most irregularities or variances due to construction methods or materials according to a study sponsored by the Board (“Dimensional Tolerances in Construction and for Surface...
-
Changes in Level at Entry to Wheelchair Spaces (M303.3)
with drop offs ½ inch or greater would be required to provide edge protection 2 inches high minimum on each side to prevent users from inadvertently travelling off the sides of the ramped surface...
-
11B-704.4.1 Height
When in use, the touch surface of TTY keypads shall be 34 inches (864 mm) minimum above the finish floor....
-
11B-308.3.2 Obstructed high reach
Operable parts of fuel dispensers shall be permitted to be 54 inches (1372 mm) maximum measured from the surface of the vehicular way where fuel dispensers are installed on existing curbs...
-
1133A.2 Clear floor space
A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows either a parallel or a forward approach shall be provided at the work surface required by Section 1133A...
-
11B-704.4.1 Height
When in use, the touch surface of TTY keypads shall be 34 inches (864 mm) minimum above the finish floor....
-
11B-308.3.2 Obstructed high reach
Operable parts of fuel dispensers shall be permitted to be 54 inches (1372 mm) maximum measured from the surface of the vehicular way where fuel dispensers are installed on existing curbs...
-
11B-703.7.2.6 Toilet and bathing facilities geometric symbols
Geometric symbols at entrances to toilet and bathing rooms shall be mounted at 58 inches (1473 mm) minimum and 60 inches (1524 mm) maximum above the finish floor or ground surface measured...
- Voters with Disabilities: Additional Monitoring of Polling Places Could Further Improve Accessibility
- Magnetic Switch (BE9023)
-
5.8.2.1 Height of Breast Platform at Time of Measurement
However, the top surface of the breast platform is a well-defined surface, and defines where the patient’s chest will be during the exam....
-
Alterations to Existing Facilities
For example, if an alteration project involves only installing pedestrian signals at existing intersections and there are no detectable warning surfaces on the curb ramps at the intersections...
-
1003.3.2 Boarding Pier Clearances
At high water, the entire chain is floating and a transition plate connects the first float to the surface of the launch ramp....
-
Slopes and Resting Intervals for Beach Access Routes
When the surface is paved or is built with boards, the cross slope is not allowed to be steeper than 1:48 (2 percent)....
-
11B-1003.3.2 Boarding pier clearances
At high water, the entire chain is floating and a transition plate connects the first float to the surface of the launch ramp....
-
Fulton County - ADA Administrator
percentages; may include the ability to perform mathematical operations with fractions; may include the ability to compute discount, interest, and ratios; may include the ability to calculate surface...
-
1.3.1 Overview of NPRM
Types of Equipment to Which Technical Criteria Applies Diagnostic Equipment Used by Patients in Supine, Prone, or Side-Lying Position (M301) Transfer surface...
-
A MINIMUM HIGHEST POINT STANDARD OF 19 INCHES IS CONSISTENT WITH EXISTING ACCESSIBILITY STANDARDS
A MINIMUM HIGHEST POINT STANDARD OF 19 INCHES IS CONSISTENT WITH EXISTING ACCESSIBILITY STANDARDS Current accessibility standards and regulations generally consider a transfer surface...
-
11B-404.2.9 Door and gate opening force
and the centerline of the second push plate shall be 30 inches (762 mm) minimum and 44 inches (1118 mm) maximum above the floor or ground surface....