University of Missouri 1-800-949-4232 adacenter@missouri.edu http://www.gpadacenter.org The contents of this factsheet were developed under grants from the National Institute on Disability...
Search Results "9-1-1 Service"
-
Small Business and ADA Readily Achievable Requirements - A Factsheet from the ADA National Network
-
Dispersion of Cells. (Section-by-Section Analysis)
Commenters recommended modification of the scoping requirements to require a percentage of accessible cells in each program, classification, use or service area....
-
II-8.3000 Transition plan
A transition plan should contain at a minimum -- 1) A list of the physical barriers in a public entity's facilities that limit the accessibility of its programs, activities, or services...
-
11B-1009.2.3 Clear deck space
The clear deck space shall have a slope not steeper than 1:48. FIGURE 11B-1009.2.3 CLEAR DECK SPACE AT POOL LIFTS...
-
ACCESSIBLE ROUTE
[DSA-AC & HCD 1-AC] A continuous unobstructed path connecting accessible elements and spaces of an accessible site, building or facility that can be negotiated by a person with a disability...
-
Evaluating Physical and Mental Qualification Standards Under the ADA
Evaluating Physical and Mental Qualification Standards Under the ADA Employers generally have two kinds of physical or mental standards: 1....
-
11B-703.7.2.7 Pedestrian traffic-control buttons
Pole-supported pedestrian traffic-control buttons shall be identified with color coding consisting of a textured horizontal yellow band 2 inches (51 mm) in width encircling the pole, and a 1-...
-
1009.2.1 Pool Lift Location
EXCEPTIONS: 1. Where the entire pool depth is greater than 48 inches (1220 mm), compliance with 1009.2.1 shall not be required. 2....
-
Sec.36.304(d)(2)
(2) If, as a result of compliance with the alterations requirements specified in paragraph (d)(1) of this section, the measures required to remove a barrier would not be readily achievable...
-
B. Notice of the ADA’s Provisions
The second administrative requirement is providing public notice about the ADA.2 There are three main considerations for providing notice: 1....
-
1132A.5.2 Strike edge maneuvering space at doors
Notes: 1. See Section 1134A for bathrooms that are required to be accessible. 2. Twenty-four inches (610 mm) is preferred for strike edge clearance....
-
PRIVATE BUILDING OR FACILITY
[DSA-AC] A place of public accommodation or a commercial building or facility subject to Chapter 1, Section 1.9.1.2. [2010 ADAS] Private Building or Facility. ...
-
11B-306.2.3 Minimum required depth
Exceptions: 1. The toe clearance shall extend 19 inches (483 mm) minimum under sinks required to be accessible by Section 11B-212.3. 2. ...
-
12206(a)(2) Publication of plan
--The Attorney General shall publish the plan referred to in paragraph (1) for public comment in accordance with subchapter II of chapter 5 of title 5, United States Code (commonly known...
-
11B-407.2.2.2 Visible signals
Exceptions: 1. Reserved. 2. Reserved. [2010 ADAS] 2. ...
-
M302.4.2 Clearance Around Base
The width of the base permitted within this clearance shall be 26 inches (660 mm) wide maximum at the edge of the examination surface and shall be permitted to increase at a rate of 1 inch...
-
M305.2.2.2 Side Transfer Supports
EXCEPTIONS: 1. Where transfer surfaces are part of an articulating surface, the support shall be permitted to be 15 inches (380 mm) long minimum. 2....
-
M301.4.2 Clearance Around Base
The width of the base permitted within this clearance shall be 26 inches (660 mm) wide maximum at the edge of the examination surface and shall be permitted to increase at a rate of 1 inch...
-
1009.4.1 Clear Deck Space
A clear deck space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
LULA Elevator Dimensions
These dimensions permit a car at least 51 inches by 51 inches provided that the door has a clear width of at least 36 inches (408.4.1, Exception 1)....
-
1016.6 Openings
Openings in the surface of outdoor recreation access routes shall not allow the passage of a sphere more than 1/2 inch (13 mm) in diameter. Advisory 1016.6 Openings. ...
-
1.2.1
The statement must attest that the work does not cause any alteration or reconstruction of structural elements nor trigger structural rehabilitation per Title 24, Part 1, Section 4-309(c...
-
229.1 General
EXCEPTION: 1. Glazed openings in residential dwelling units required to comply with 809 shall not be required to comply with 229. 2....
-
M301.3.1 Transfer Supports (Section-by-Section Analysis)
The only change in the final rule was to update the cross reference to applicable transfer surfaces to accommodate the changes made to transfer surfaces, described above in Section IV.B.1....