If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars....
Search Results "Vertical Alignment"
-
11B-608.6 Shower spray unit and water
-
11B-233.3.1.1 Residential dwelling units with mobility features
ETA Editor's Note At this point, the alignment of 2013 CBC section numbering with 2010 ADAS becomes inconsistent. ...
-
11B-233.3.1.1 Residential dwelling units with mobility features
ETA Editor's Note At this point, the alignment of CBC section numbering with 2010 ADAS becomes inconsistent. ...
-
11B-705.2 Detectable directional texture
This surface will be placed directly behind the yellow detectable warning texture specified in Section 11B-705.1.2.1, aligning with all doors of the transit vehicles where passengers will...
-
1133A.2 Clear floor space
The centerline of the 30-inch (762 mm) by 48-inch (1219 mm) clear floor space provided for parallel or forward approach shall be aligned with the centerline of the work space, appliance...
-
d-vii
If the ramp or landing has a vertical drop-off on either side of the ramp, is edge protection provided? [ADA Standards § 4.8.7] Yes No...
-
M305.2.2 Structural Strength
Transfer supports and their connections shall be capable of resisting vertical and horizontal forces of 250 pounds (1,112 N) applied at all points on the transfer support....
-
232.1 General
Florida vertical accessibility requirements of s.553.509, F.S., as incorporated in section 201.1.1 require vertical access to all levels of facilities....
-
1012.2 Height
Guards shall form a protective barrier not less than 42 inches (1067 mm) high, measured vertically above the leading edge of the tread, adjacent walking surface or adjacent seatboard....
-
10.3.1(9)
(9) In stations covered by this section, rail-to-platform height in new stations shall be coordinated with the floor height of new vehicles so that the vertical difference, measured when...
-
5.9 Standing Support Recommendations for M304 Diagnostic Equipment Used by Patients in a Standing Position
These standing supports may be provided in a horizontal position, vertical position, or a combination of horizontal and vertical positions, as long as the minimum length of gripping surface...
-
1013.3 Height
Required guards shall not be less than 42 inches (1067 mm) high, measured vertically as follows: 1. From the adjacent walking surfaces; 2. ...
-
1015.3 Height
Required guards shall not be less than 42 inches (1067 mm) high, measured vertically as follows: From the adjacent walking surfaces....
-
11B-233.2 Reserved
. ◼ ETA Editor's Note At this point, the alignment of CBC section numbering with 2010 ADA Standards becomes inconsistent....
-
11B-233.2 Reserved
. ◼ ETA Editor's Note At this point, the alignment of CBC section numbering with 2010 ADA Standards becomes inconsistent....
-
11B-703.7.2.6.3 Unisex toilet and bathing facilities
The vertices of the triangle shall be located ¼ inch (6.4 mm) maximum from the edge of the circle....
-
11B-703.7.2.6.3 Unisex toilet and bathing facilities
The vertices of the triangle shall be located ¼ inch (6.4 mm) maximum from the edge of the circle....
-
2. Question: What is the minimum width needed for a level boarding railroad passenger station platform to meet the accessibility requirements of the Americans with Disabilities Act (ADA)?
For a level boarding island passenger platform with vertical pedestrian access (by elevator, stairs, escalators, etc.), the minimum width should be the width of the vertical access facility...
-
11B-411.2.1.4.1.1 Arrangement
Buttons shall be arranged in columns to the right of the keypad with a minimum horizontal spacing of 1.5 times the horizontal spacing between the numeric keys and with the same vertical...
-
11B-411.2.1.4.1.1 Arrangement
Buttons shall be arranged in columns to the right of the keypad with a minimum horizontal spacing of 1.5 times the horizontal spacing between the numeric keys and with the same vertical...
-
11B-411.2.1.4.1.1 Arrangement
Buttons shall be arranged in columns to the right of the keypad with a minimum horizontal spacing of 1.5 times the horizontal spacing between the numeric keys and with the same vertical...
-
10.3.2(4)
(4) In light rail, rapid rail and commuter rail key stations, the platform or a portion thereof and the vehicle floor shall be coordinated so that the vertical difference, measured when...
-
602.5 Spout Location
The spout shall be located 15 inches (380 mm) minimum from the vertical support and 5 inches (125 mm) maximum from the front edge of the unit, including bumpers....
-
11B-602.5 Spout location
The spout shall be located 15 inches (381 mm) minimum from the vertical support and 5 inches (127 mm) maximum from the front edge of the unit, including bumpers....