[See subsections ...]
Search Results "Transfer System"
-
219 and 706 Assistive Listening Systems
-
11B-706 ASSISTIVE LISTENING SYSTEMS
[See subsections ...]
-
11B-219 ASSISTIVE LISTENING SYSTEMS
[See subsections ...]
-
11B-706 Assistive listening systems
[See subsections ...]
-
708 Two-Way Communication Systems
[See subsections ...]
-
Key Study findings:
wouldn’t attempt to transfer at all and 3 of which attempted the transfer but failed in the process). ...
-
M305.2.2 Structural Strength
Transfer supports and their connections shall be capable of resisting vertical and horizontal forces of 250 pounds (1,112 N) applied at all points on the transfer support....
-
Backrests
Backrests: The backrest design for platform 1, the first surface that participants transferred to from their WMD as seen in Table 2, was based on bench seat back supports in section 903.5...
-
M302.3.1 Transfer Supports (Section-by-Section Analysis)
In the MDE NPRM the Access Board proposed that transfer supports must be provided for use with transfer sides on diagnostic equipment used by patients in the seated position, and that these...
- Listen Technologies ADA Standard Stationary IR Assistive Listening System
-
§ 37.3 Automated guideway transit system or AGT
Automated guideway transit system or AGT means a fixed-guideway transit system which operates with automated (driverless) individual vehicles or multi-car trains....
-
5.3.2.2 Transfer Sides for Imaging Equipment
5.3.2.2 Transfer Sides for Imaging Equipment. The transfer surface should be provided on at least one long side of the table....
-
5.4.2.2 Transfer and Positioning Support Length for Imaging Equipment with Transfer Surfaces
5.4.2.2 Transfer and Positioning Support Length for Imaging Equipment with Transfer Surfaces....
-
903.3.1.1.1 Exempt locations
Automatic sprinklers shall not be required in the following rooms or areas where such rooms or areas are protected with an approved automatic fire detection system in accordance with Section...
- Sennheiser SI 30 Master Transmitter
-
How to Measure Transfer Surface Height
How to Measure Transfer Surface Height Regardless of the final decision on the low height measurement, the Subcommittee agreed that the height of the transfer surface would be measured...
-
11B-1002.6.3 Wheelchair storage space
Wheelchair storage spaces complying with Section 11B-305 shall be provided in or adjacent to unload areas for each required transfer device and shall not overlap any required means of egress...
-
11B-1002.6.3 Wheelchair storage space
Wheelchair storage spaces complying with Section 11B-305 shall be provided in or adjacent to unload areas for each required transfer device and shall not overlap any required means of egress...
-
11B-1002.6.3 Wheelchair storage space
Wheelchair storage spaces complying with Section 11B-305 shall be provided in or adjacent to unload areas for each required transfer device and shall not overlap any required means of egress...
-
Shower Stalls (ADAAG 4.21)
Shower Stalls (ADAAG 4.21) Although ADAAG permits both transfer and a roll-in showers, roll-in showers were found in institutional facilities....
-
1002.6.3 Wheelchair Storage Space
Wheelchair storage spaces complying with 305 shall be provided in or adjacent to unload areas for each required transfer device and shall not overlap any required means of egress or accessible...
-
§ 37.3 Fixed route system
Fixed route system means a system of transporting individuals (other than by aircraft), including the provision of designated public transportation service by public entities and the provision...
-
5.2.2 Transfer Surface Size Recommendations for M302
5.2.2 Transfer Surface Size Recommendations for M302 Description: The transfer surface is the part of the diagnostic equipment onto which patients who use mobility devices or aids transfer...
-
5.4.2.2 Transfer and Positioning Support Length Recommendations for Imaging Equipment with Transfer Surfaces
5.4.2.2 Transfer and Positioning Support Length Recommendations for Imaging Equipment with Transfer Surfaces On imaging equipment with transfer surfaces, the transfer surface is oriented...