All steps on a flight of stairs shall have uniform riser heights and uniform tread depths. Risers shall be 4 inches (100 mm) high minimum and 7 inches (180 mm) high maximum....
Search Results "Table Height"
Commonly Searched Documents
-
504.2 Treads and Risers
- Figure 505.4 Handrail Height – Drawing from the U.S. Access Board
-
504.2 Treads and Risers
All steps on a flight of stairs shall have uniform riser heights and uniform tread depths. Risers shall be 4 inches (100 mm) high minimum and 7 inches (180 mm) high maximum....
-
504.2 Treads and Risers
All steps on a flight of stairs shall have uniform riser heights and uniform tread depths. Risers shall be 4 inches (100 mm) high minimum and 7 inches (180 mm) high maximum....
-
904.3.2 Counter
The counter surface height shall be 38 inches (965 mm) maximum above the finish floor or ground....
-
11B-904.3.2 Counter
The counter surface height shall be 38 inches (965 mm) maximum above the finish floor or ground....
-
904.3.2 Counter
The counter surface height shall be 38 inches (965 mm) maximum above the finish floor or ground....
-
Picnic Facilities
[See subsections ...]
-
11B-249.1 General
Adult changing facilities shall comply with Section 11B-249.
-
11B-249 Adult changing facilities
[See subsections ...]
-
11B-249.1.1
Where adult changing facilities are provided, each adult changing facility shall comply with Section 11B-813.
-
11B-813 Adult changing facilities
Adult changing facilities shall comply with Section 11B-813. ETA Editor's Note Adult changing facilities are not addressed by 2010 ADA Standards, although a case could be...
- Midmark 647 Barrier-Free® Power Podiatry Procedures Chair
-
M301.4 Lift Compatibility (Section-by-Section Analysis)
The MDE NPRM proposed to require that diagnostic equipment used by patients in the supine, prone, or side-lying position be usable with a patient lift and comply with either the...
-
5.4.7 Transfer Support Gripping Surface Clearance Recommendation for M301 and M302
5.4.7 Transfer Support Gripping Surface Clearance Recommendation for M301 and M302 Description: A clearance around the gripping surface is necessary to ensure sufficient space for...
-
5.7 Lift Compatibility
5.7 Lift Compatibility.
-
5.4.7 Transfer Support Gripping Surface Clearance for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.7 Transfer Support Gripping Surface Clearance for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position. There should be a 1½ inches minimum clearance around the...
-
5.7 Lift Compatibility Recommendations
5.7 Lift Compatibility Recommendations
-
5.4.4 Transfer Support Distance From Transfer Surface for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.4 Transfer Support Distance From Transfer Surface for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position. The transfer support should be located a maximum distance...
-
9.2* POST OFFICE LOBBIES
Where writing desks or tables are provided, a minimum of at least one writing desk or table that complies with 4.32 must be provided....
-
11B-604.9 Water closets and toilet compartments for children's use
When the exception in Section 11B-604.1 is used, the suggested dimensions of Table 11B-604.9 for a single age group shall be applied consistently to the installation of a water closet and...
-
602.4 Spout Height
Spout outlets shall be 36 inches (915 mm) maximum above the finish floor or ground.
-
602.4 Spout Height
Spout outlets shall be 36 inches (915 mm) maximum above the finish floor or ground.
-
4.15.2* Spout Height
Spouts shall be no higher than 36 in (915 mm), measured from the floor or ground surfaces to the spout outlet (see Fig. 27(a)).