When one or more shower stalls are provided within the same dwelling unit, at least one shower stall shall comply with one of the following requirements....
Search Results "Shower Room"
-
1134A.6, Item 1
-
1134A.6, Item 1
When one or more shower stalls are provided within the same dwelling units, at least one shower stall shall comply with one of the following requirements....
-
Machinery Spaces: ADA Standard Section 203.5
Section 203.5 covers scoping requirements of general exceptions for machinery spaces in the most current ADA Standards.
-
11B-203.5 Machinery spaces
Machinery spaces include, but are not limited to, elevator pits or elevator penthouses; mechanical, electrical or communications equipment rooms; piping or equipment catwalks; water or sewage...
-
11B-203.5 Machinery spaces
Machinery spaces include, but are not limited to, elevator pits or elevator penthouses; mechanical, electrical or communications equipment rooms; piping or equipment catwalks; water or sewage...
- Bobrick Reversible Folding Shower Seat B-5181
- Speakman Versatile ADA Handheld Shower System SM-5490-ADA
-
241 Saunas and Steam Rooms
241 Saunas and Steam Rooms...
- Speakman Versatile Handheld Shower System SM-5060
-
11B-223.1.1 Alterations
Where patient bedrooms or resident sleeping rooms are altered or added, the requirements of Section 11B-223 shall apply only to the patient bedrooms or resident sleeping rooms being altered...
-
11B-223.1.1 Alterations
Where patient bedrooms or resident sleeping rooms are altered or added, the requirements of Section 11B-223 shall apply only to the patient bedrooms or resident sleeping rooms being altered...
-
D. Beds in accessible guest rooms and sleeping rooms
Beds in accessible guest rooms and sleeping rooms The Department is considering regulating the accessibility of beds in accessible guest rooms and sleeping rooms, such as dormitories...
-
Alterations: ADA Standard Section 223.1.1
Section 223.1.1 ADA Standards for alterations to medical care and long-term care facilities.
- American Bath Enterprises, Inc. AccessaBath Shower System
-
4.26.3(1)
(1) Bending stress in a grab bar or seat induced by the maximum bending moment from the application of 250 lbf (1112N) shall be less than the allowable stress for the material of the...
-
4.26.3(4)
(4) Tensile force induced in a fastener by a direct tension force of 250 lbf (1112N) plus the maximum moment from the application of 250 lbf (1112N) shall be less than the allowable...
-
4.26.3(2)
(2) Shear stress induced in a grab bar or seat by the application of 250 lbf (1112N) shall be less than the allowable shear stress for the material of the grab bar or seat. If the...
-
4.26.3(3)
(3) Shear force induced in a fastener or mounting device from the application of 250 lbf (1112N) shall be less than the allowable lateral load of either the fastener or mounting...
-
SECTION 1135A LAUNDRY ROOMS
[See subsections ...]
-
SECTION 1135A LAUNDRY ROOMS
[See subsections ...]
- Symmons® Allura Tub/Hand Shower System S-4705
-
11B-610.3.2 L-shaped seats
FIGURE 11B-610.3.2 L-SHAPED SHOWER SEAT...
-
11B-224.1.3 Range of accommodations
Accessible guest rooms or suites shall be dispersed among the various classes of sleeping accommodations to provide a range of options applicable to room sizes, costs, and amenities provided...
-
11B-224.1.3 Range of accommodations
Accessible guest rooms or suites shall be dispersed among the various classes of sleeping accommodations to provide a range of options applicable to room sizes, costs, and amenities provided...