EVCS complying with Section 11B-812 shall be provided in accordance with Section 11B-228.3.2 for each combination of charging level and EV connector type integral to the EV charger....
Search Results "Raised Courtroom Station"
Commonly Searched Documents
-
11B-228.3.2 Minimum number
- Seton Custom Sized Braille Signs L2852
-
Numeric Keys: ADA Standard Section 707.6.2
Numeric keys shall be arranged in a 12-key ascending or descending telephone keypad layout. The number five key shall be tactilely distinct from the other keys. Advisory 707.6.2...
-
11B-707.6.2 Numeric keys
Numeric keys shall be arranged in a 12-key ascending or descending telephone keypad layout. The number five key shall be tactilely distinct from the other keys. Advisory...
-
1012.1 General
section contains the technical requirements for parking spaces provided within camping units and picnic units with mobility features and pull-up spaces for recreational vehicles at dump stations...
- Takeform Fusion Signage Office/Suite/Room Identification Type G
- Takeform Fusion Signage Office/Suite/Room Identification Type F
- Takeform Fusion Signage Office/Suite/Room Identification Type G.2
- Takeform Fusion Signage Office/Suite/Room Identification Type I
- Takeform Fusion Signage Office/Suite/Room Identification Type H
-
M303.2.6 Edge Protection
Where wheelchair spaces are provided on a platform raised more than 1 ½ inches (38 mm) in height, edge protection 2 inches (51 mm) high minimum measured from the surface of the platform...
-
11B-250.1 General
Physical separation shall be provided with circulation paths raised 4 inches (102 mm) minimum above the area where vehicular traffic occurs....
- ADA Sign Depot Meeting Room Sign with Tactile Text and Grade 2 Braille - 8" x 4"
-
[F] 907.4.2.2 Height
[F] 907.4.2.2 Height. The height of the manual fire alarm boxes shall be a minimum of 42 inches (1067 mm) and a maximum of 48 inches (1219 mm) measured vertically, from the floor...
-
ACCESSIBLE ROUTE & PATH OF TRAVEL QUESTIONS:
[See subsections ...]
-
There does not seem to be a distinction between different EVCS standards (Level 1, Level 2, DC CHAdeMO, DC CCS, and Tesla). Does the schedule defined in Table 11B-228.3.2.1 make a distinction between the different types of EVSE standards or are that all considered to equivalently be an EVCS?
RESPONSE: The CBC Chapter 11B accessibility requirements for EVCS do not distinguish between the different EVCS standards like those listed. However, building officials may view...
-
907.2.7 Group M
A manual fire alarm system shall be installed in Group M occupancies having an occupant load of 500 or more persons or more than 100 persons above or below the lowest level of exit...
-
907.2.7.1 Occupant notification
During times that the building is occupied, in lieu of the automatic activation of alarm notification appliances, the manual fire alarm system shall be allowed to activate an alarm...
-
Requirements to Remember for: Commuter Rail Projects
[See subsections ...]
-
10.3.1(8)
(8) Platform edges bordering a drop-off and not protected by platform screens or guard rails shall have a detectable warning. Such detectable warnings shall comply with 4.29.2 and...
-
11B-812.7.3 Lettering
The words “NO PARKING” shall be painted on the surface within each access aisle in letters a minimum of 12 inches (305 mm) in height and located to be visible from the adjacent...
-
11B-812.10 Electric vehicle chargers
[See subsections ...]
-
11B-812.10.1 General
EV chargers shall comply with Section 11B-812.10.
-
11B-812.7.3 Lettering
The words “NO PARKING” shall be painted on the surface within each access aisle in letters a minimum of 12 inches (305 mm) in height and located to be visible from the adjacent...