How to use Guldmann GH3 ceiling lift system for horizontal lifting. Read more at http://www.guldmann.net/ceiling-lifts. Watch more videos on http://www.youtube.com/vguldmann
Search Results "Intensive Care Patient Room"
Commonly Searched Documents
- Guldmann GH3 Ceiling Lift - Horizontal Lifting
- Guldmann GH3 Ceiling Lift System
- Guldmann GLS 5 Mobile Lifter - Instruction Video
- Guldmann Mobile Lifter GL5: Lifting from bed to wheelchair
- Guldmann Ceiling Hoist: GH3 Ceiling Lift - Presentation
- Guldmann Mobile Lifter GL5: Lifting from wheelchair
-
M301.4 Lift Compatibility (Section-by-Section Analysis)
The MDE NPRM proposed to require that diagnostic equipment used by patients in the supine, prone, or side-lying position be usable with a patient lift and comply with either the proposed...
-
SECTION 1135A LAUNDRY ROOMS
[See subsections ...]
-
SECTION 1135A LAUNDRY ROOMS
[See subsections ...]
-
11B-224.1.3 Range of accommodations
Accessible guest rooms or suites shall be dispersed among the various classes of sleeping accommodations to provide a range of options applicable to room sizes, costs, and amenities provided...
-
5.2.1.3 Transfer Surface Size for Stretchers
5.2.1.3 Transfer Surface Size for Stretchers. The transfer surface should be 28 inches wide minimum and 17 inches deep minimum located on both long sides of stretchers.
-
5.4.1.1 Transfer Support Location for Stretchers
5.4.1.1 Transfer Support Location for Stretchers. The transfer surface for stretchers should be oriented along the long side of the surface.
-
Single-User Toilet Rooms: Split Plumbing
Single-User Toilet Rooms: Split Plumbing Water closets and lavatories can be located on opposing walls....
-
M305.2.2 Length (Section-by-Section Analysis)
The Committee explained that the transfer support length provides the gripping surface for the patient to grasp or maintain balance while transferring....
-
Hospital Outpatient Facilities [§208.2.1]
At least 10% of patient and visitor parking spaces that serve such facilities must comply....
-
224 Transient Lodging Guest Rooms
The minimum number of guest rooms required to be accessible in transient lodging facilities is covered in section 224....
-
5.2.1.1 Transfer Surface Width Recommendations for M301
The discussion of transfer surface width triggered the decision to set aside the issues of equipment for very large or obese patients....
-
5.4.10 Transfer Support Fittings for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
The transfer supports shall not rotate when locked in place for patient transfer or use....
-
§ 36.406(c)(1) Guest rooms
(1) Guest rooms. Guest rooms with mobility features in places of lodging subject to the transient lodging requirements of 2010 Standards shall be provided as follows –...
-
c. Transfer Surface Size for Diagnostic Equipment Used by Patients in the Supine, Prone, or Side-lying Position
the patient for proper exam....
-
11B-224.8.1 More than 25-bed sleeping rooms
In sleeping rooms with more than 25 beds, a minimum of 5 percent of the beds shall have clear floor space complying with Section 11B-806.2.3....
-
Needs Photos or Technical Info
Are these patient rooms designed only for those with cognitive impairments? I really want more information!...
-
5.4.10 Transfer Support Fittings Recommendations for M301 and M302
The Committee recommends transfer supports not rotate when locked in place for patient transfer or use....
-
11B-803.6 Mirrors
Mirrors shall be installed with the bottom edge of the reflecting surface 20 inches (508 mm) maximum above the finish floor or ground. Mirrors shall be full length with a reflective...