The clear floor or ground space shall be 30 inches (760 mm) minimum by 48 inches (1220 mm) minimum. Figure 305.3 Clear Floor or Ground Space...
Search Results "Ceramic Tile Flooring"
-
305.3 Size
-
804.6.3 Dishwasher
Clear floor or ground space shall be positioned adjacent to the dishwasher door....
- Allen Face F-Meter® Rolling Floor Profiler
-
11B-604.3.1 Size
ETA Editor's Note The CBC 11B-604.3.1 requirement for maneuvering space in front of accessible water closets exceeds the 2010 ADA Standards requirement for water closet clear floor...
-
11B-604.3.1 Size
ETA Editor's Note The CBC 11B-604.3.1 requirement for maneuvering space in front of accessible water closets exceeds the 2010 ADA Standards requirement for water closet clear floor...
-
11B-404.2.4.4 Floor or ground surface
Floor or ground surface within required maneuvering clearances shall comply with Section 11B-302. Changes in level are not permitted. Exceptions: 1. ...
-
11B-404.2.4.4 Floor or ground surface
Floor or ground surface within required maneuvering clearances shall comply with Section 11B-302. Changes in level are not permitted. Exceptions: 1....
- Aluminum Dove Tail Series Pressure-Locked Grating
-
11B-703.5.6 Height from finish floor or ground
Visual characters shall be 40 inches (1016 mm) minimum above the finish floor or ground....
-
11B-703.5.6 Height from finish floor or ground
Visual characters shall be 40 inches (1016 mm) minimum above the finish floor or ground. Exceptions: 1. ...
-
Bench: ADA Standard Section 612.2
Section 612.2 covers the current ADA Standards for benches in saunas and steam rooms.
-
407.2.3.1 Floor Designation
407.2.3.1 Floor Designation. Floor designations complying with 703.2 and 703.4.1 shall be provided on both jambs of elevator hoistway entrances....
-
603.2.3 Door Swing
Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space. EXCEPTIONS: 1....
-
11B-813.2.10 Door swing
Where a clear floor space complying with Section 11B-305.3 is provided within the room beyond the arc of the door swing, doors shall be permitted to swing into the clear floor space, clearance...
-
11B-612.2 Bench
Doors shall not swing into the clear floor space required by Section 11B-903.2....
-
11B-612.2 Bench
Doors shall not swing into the clear floor space required by Section 11B-903.2....
-
11B-813.2.10 Door swing
Where a clear floor space complying with Section 11B-305.3 is provided within the room beyond the arc of the door swing, doors shall be permitted to swing into the clear floor space, clearance...
-
11B-305.7.1 Forward approach
Alcoves shall be 36 inches (914 mm) wide minimum where the depth exceeds 24 inches (610 mm).
-
11B-305.7.2 Parallel approach
Alcoves shall be 60 inches (1524 mm) wide minimum where the depth exceeds 15 inches (381 mm).
-
Forward Approach: ADA Standard Section 305.7.1
Section 305.7.1 covers the current ADA Standards for the clear floor or ground space required for forward approach.
-
Parallel Approach: ADA Standard Section 305.7.2
Section 305.7.2 covers the current ADA Standards for the clear floor or ground space required for parallel approach.
-
Clearance: ADA Standard Section 608.2.2.1
Section 608.2.2.1 covers the current ADA Standards for the clearances of standard roll-in type shower compartments.
-
11B-305.7.1 Forward approach
Alcoves shall be 36 inches (914 mm) wide minimum where the depth exceeds 24 inches (610 mm).
-
11B-305.7.2 Parallel approach
Alcoves shall be 60 inches (1524 mm) wide minimum where the depth exceeds 15 inches (381 mm).