along open-sided walking surfaces, including mezzanines, equipment platforms, aisles, stairs, ramps and landings that are located more than 30 inches (762 mm) measured vertically to the floor...
Search Results "Lavatory Clear Floor Space"
-
1015.2 Where required
- Gamco Automatic Wall-Mounted Foam Soap Dispenser - G-950FA
-
12101(b)(2)
(2) to provide clear, strong, consistent, enforceable standards addressing discrimination against individuals with disabilities;...
-
R407.6.3 Length
The landing clear length shall be 1.5 m (5.0 ft) long minimum....
-
405.7.3 Length
The landing clear length shall be 60 inches (1525 mm) long minimum....
-
EXTREME WEATHER
Cooling centers are air conditioned spaces such as senior centers, community centers, public libraries, and other public facilities that typically operate during daytime hours and are free...
-
Residential Facilities: ADA Standard Section 208.3.2
Section 208.3.2 covers scoping requirements in the current ADA Standards for the location of parking spaces in residential facilities.
-
4.3.4 Knee and Toe Clearances
4.3.4 Knee and Toe Clearances Adequate space without an obstruction under a design element to the floor is essential for WhMD users to approach sufficiently close in a forward direction...
-
11B-502.8.2 Lettering
The additional sign shall clearly state in letters with a minimum height of 1 inch (25 mm) the following: "Unauthorized vehicles parked in designated accessible spaces not displaying...
-
11B-502.8.2 Lettering
The additional sign shall clearly state in letters with a minimum height of 1 inch (25 mm) the following: "Unauthorized vehicles parked in designated accessible spaces not displaying...
-
e-iv
Are the highest floor control buttons mounted no more than 54 inches above the floor for a side reach or 48 inches for forward reach? [ADA Standards § 4.10.12 (3)] Yes No...
-
11B-707.3 Operable parts
Unless a clear or correct key is provided, each operable part shall be able to be differentiated by sound or touch, without activation....
-
11B-707.3 Operable parts
Unless a clear or correct key is provided, each operable part shall be able to be differentiated by sound or touch, without activation....
-
11B-202 Existing buildings and facilities
INTERPRETATION For the purposes of this CAN, the specific area of alteration is equivalent to the altered element or space described in Section 11B-202.3 in this CAN....
-
11B-411.4.1 Car dimensions
Inside dimensions of elevator cars and clear width of elevator doors shall comply with Section 11B-407.4.1....
-
R407.6.2 Width
The landing clear width shall be at least as wide as the widest ramp run leading to the landing....
-
11B-411.4.1 Car dimensions
Inside dimensions of elevator cars and clear width of elevator doors shall comply with Section 11B-407.4.1....
-
11B-411.4.1 Car dimensions
Inside dimensions of elevator cars and clear width of elevator doors shall comply with Section 11B-407.4.1....
-
405.7.2 Width
The landing clear width shall be at least as wide as the widest ramp run leading to the landing....
-
Initial Measures and Transfer Setup
The device seat to floor height was measured as the linear distance between the front of the seat, center-line point on top of the cushion (if present) and the floor (Figure 3 left). ...
- LaCantina Multi-slide Contemporary Clad Sliding Door System
-
M301.4.1 Clearance in Base (Section-by-Section Analysis)
The MDE NPRM proposed certain clearance requirements beneath the diagnostic equipment to allow sufficient space for the legs of a portable patient lift to fit underneath the equipment so...
- UltraPlay Ramp
- Pressalit Care PLUS Support Arm Fixed Height Swing Grab Bar