The armrest positioned opposite the water shall be removable or shall fold clear of the seat when the seat is in the raised (load) position....
Search Results "Shower Clear Floor Space"
-
11B-1009.2.6 Footrests and armrests
-
Car Controls
...are the highest floor control buttons in the elevator(s) mounted within 54" of the floor, with associated raised letters and Braille characters?...
-
5c.
Are the highest floor control buttons in the elevator cab mounted no more than 54 inches above the floor for a side reach or 48 inches for forward reach? Yes _____ No _____...
-
Alterations: ADA Standard Section 202.3
Section 202.3 covers the most current requirements for alterations in existing building and facilities.
-
12101(b)(1)
(1) to provide a clear and comprehensive national mandate for the elimination of discrimination against individuals with disabilities;...
-
405.7.2 Width
The landing clear width shall be at least as wide as the widest ramp run leading to the landing....
-
11B-405.7.2 Width
The landing clear width shall be at least as wide as the widest ramp run leading to the landing....
-
11B-405.7.2 Width
The landing clear width shall be at least as wide as the widest ramp run leading to the landing....
-
11B-405.7.2 Width
The landing clear width shall be at least as wide as the widest ramp run leading to the landing....
-
405.7.2 Width
The landing clear width shall be at least as wide as the widest ramp run leading to the landing....
- UltraPlay Ramp
-
Wading pools. (Section-by-Section Analysis)
Several commenters felt that the required clear deck space surrounding a pool provided sufficient space for a sloped entry during alterations....
-
M301.2.1, M302.2.1 Transfer Height
Transfer Height Proposed requirement: The height of the transfer surface during patient transfer shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured from the floor...
-
Building Guidelines and Standards are needed for Accommodations of Low Vision Persons
All these things should be easily found by the person who negotiates these spaces....
-
4.34.6.5(1)
(1) The sink and surrounding counter shall be mounted at a maximum height of 34 in (865 mm) above the floor, measured from the floor to the top of the counter surface, or shall be adjustable...
-
Section 1.0 Background
The analysis was limited to WhMD dimensions, minimum clear floor areas, space requirements for maneuvering, knee and toe clearances, and reach limits....
-
11B-407.2.2.1 Visible and audible signals
Where in-car signals are provided, they shall be visible from the floor area adjacent to the hall call buttons. Exceptions: Reserved. Reserved....
-
11B-604.7.2 Disposal units
The disposal unit shall be located below the grab bar with the opening of the disposal unit 19 inches minimum (483 mm) above the finish floor....
-
11B-803.6 Mirrors
Mirrors shall be installed with the bottom edge of the reflecting surface 20 inches (508 mm) maximum above the finish floor or ground....
-
11B-306.3.4 Clearance reduction
Between 9 inches (229 mm) and 27 inches (686 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches...
-
11B-803.6 Mirrors
Mirrors shall be installed with the bottom edge of the reflecting surface 20 inches (508 mm) maximum above the finish floor or ground....
-
11B-604.7.2 Disposal units
The disposal unit shall be located below the grab bar with the opening of the disposal unit 19 inches minimum (483 mm) above the finish floor....
-
11B-306.3.4 Clearance reduction
Between 9 inches (229 mm) and 27 inches (686 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches...
-
11B-407.2.1.1 Height
[2010 ADA Standards] EXCEPTION: Existing call buttons and existing keypads shall be permitted to be located at 54 inches (1370 mm) maximum above the finish floor, measured to the centerline...