Retrofitted vehicles shall be coordinated with the platform in existing stations such that the horizontal gap shall be no greater than 4 inches and the height of the vehicle floor, under...
Search Results "Urinal Clear Floor Space"
Commonly Searched Documents
-
§ 38.113(d)(4) Exception
-
11B.707.7.1.1 Vertically mounted display screen
mounted vertically or tipped away from the viewer less than 30 degrees, the center line of the display screen and other display devices shall be no more than 52 inches (1321 mm) above the floor...
- Guldmann Basic High Sling
-
Technical Memorandum TM 2013-22 Storage (Kitchens and Kitchenettes)
Access Board “shelf space” shall be calculated by linear feet and drawers shall be considered shelving for purposes of determining compliance with TAS 804.5....
-
11B-606.3 Height
Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (864 mm) maximum above the finish floor or ground....
-
Some existing measurement protocols
Some existing measurement protocols Currently there are no generally accepted measurement protocols for determining the slope, flatness, or waviness of floor surfaces in terms of accessibility...
-
11B-606.3 Height
Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (864 mm) maximum above the finish floor or ground....
-
1009.8 Two-way communication
A two-way communication system complying with Sections 1009.8.1 and 1009.8.2 shall be provided at the landing serving each elevator or bank of elevators on each accessible floor that is...
-
5) Areas of rescue assistance or places of refuge
5) Areas of rescue assistance or places of refuge ADAAG: Areas of rescue assistance (safe areas in which to await help in an emergency) are generally required on each floor, other than the...
-
11B-606.3 Height
Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (864 mm) maximum above the finish floor or ground....
-
2. Protruding Objects
Accessible element or space ANSI A117.1 section APPLICATION 2....
-
12. Seating, tables, or work surfaces
Accessible element or space ANSI A117.1 section APPLICATION 12....
-
4.6.5* Vertical Clearance
At parking spaces complying with 4.1.2(5)(b), provide minimum vertical clearance of 98 in (2490 mm) at the parking space and along at least one vehicle access route to such spaces from site...
-
Courtesy Phones
The Board has interpreted the reference to "public telephones" as including courtesy phones but has included a specific reference to them in 217.1 so that their coverage is clear....
-
Footrests and Armrests
Armrests are not required, however if provided, the armrest opposite the water must be removable or be able to fold clear of the seat when the seat is in the raised (load) position....
-
What Are the Requirements for Accessible Routes?
This section describes the various features of accessible routes within a play area, including location, clear width, slope, and accessible surfaces. ...
-
405.8 Handrails
Ramps not subject to the exception to 405.5 shall be designed to maintain a 36 inch (915 mm) minimum clear width when handrails are installed....
-
608.2.3 Alternate Roll-In Type Shower Compartments
Alternate roll-in type shower compartments shall be 36 inches (915 mm) wide and 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
11B-505.5 Clearance
Handrails may be located in a recess if the recess is 3 inches (76 mm) maximum deep and 18 inches (457 mm) minimum clear above the top of the handrail. [2010 ADAS] 505.5 Clearance. ...
-
11B-411.2.1.3.2 Touch screen call console arrangement
The accessibility function button shall be located at a height of 36 inches (914 mm) to 42 inches (1067 mm) above the finish floor....
-
11B-411.2.1.3.1 Keypad call console arrangement
The accessibility function button shall be located directly below the keypad at a height of 36 inches (914 mm) to 42 inches (1067 mm) above the finish floor....
-
1132A.4, Item 5
In buildings containing covered multifamily dwelling units, the floor or landing immediately outside the entry may be sloped up to ¼ inch (6.35 mm) per foot (12 inches) (305 mm), in a direction...
-
11B-203.13 Raised boxing or wrestling rings
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
-
11B-308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1219 mm) maximum and the low forward reach shall be 15 inches (381 mm) minimum above the finish floor or...