administrative fixed costs of or relating to the following types of improvements: (1) installation of missing curb ramps; (2) repair of damage that tree roots have caused to sidewalk or walkway surfaces...
Search Results "Floor Surface"
-
1. Access Barrier Removal in Existing Pedestrian Facilities
-
Comparison of Single-User Toilet Room Layouts: 2A, 2B, and 2C
The in-swinging door increases overall room size because it cannot swing over the required clear floor space at any accessible fixture, (see section 4.22.2 of the 1991 Standards)....
-
Components (M303.4)
M303.4.1 would require the height of the breast platform to be 30 inches (760 mm) high minimum and 42 inches (1065 mm) high maximum above the floor when mammography equipment is used by...
-
Weight Scales
Unit costs are presented for wheelchair scales with raised platforms and with flush platforms in the floor....
-
Section 4.1.3, Accessible Buildings: New Construction (Preamble, Section-by-Section Analysis)
Sections 4.1.3 (1) through (4) cover accessible routes, protruding objects, ground and floor surfaces, and stairs....
-
804 Kitchens and Kitchenettes
For example, requirements for clearances in pass through and U-shaped kitchens apply only to kitchens with cook tops or conventional ranges (804.2), and specified kitchen work surfaces are...
-
Section 4.1.3, Accessible Buildings: New Construction (Section-By-Section Analysis and Response to Comments)
Sections 4.1.3 (1) through (4) cover accessible routes, protruding objects, ground and floor surfaces, and stairs....
-
8.4 Improving Data Sources and Research
For example, the Committee was making recommendations about standards for transfer surfaces of certain sizes....
-
1132A.8 Hand-activated door hardware
Hand-activated door latching, locking and opening hardware shall be centered between 30 inches (762 mm) and 44 inches (1118 mm) above the floor....
-
308.2.2 Obstructed High Reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
-
610.2 Bathtub Seats
The top of bathtub seats shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the bathroom finish floor....
-
Adaptability
Rooms need to be designed to provide required clear floor space at fixtures, turning space, and door clearance....
-
Stacks [8.5]
Stacks [8.5] Elements fixed to stacks, such as ladders, cannot reduce the minimum passage width nor should signs or other elements between 27 to 80 inches above the floor project more...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding No Weight - Side Approach Power Chair
abilities of power chair users represented as the percentage of users expected to reach to a target location in the lateral or sideways reach direction for a given (a) height from the floor...
-
4.1.2(8)
(8) At least one principal entrance at each grade floor level to a building or facility shall comply with 4.14, Entrances....
-
1014.1 General
The technical requirements address the entrance to camp shelters (1014.2), including transfer access (1014.2.1) and roll-in access (1014.2.2); and the floor within camp shelters (1014.3)...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding No Weight - Side Approach Manual Wheelchair
abilities of manual chair users represented as the percentage of users expected to reach to a target location in the lateral or sideways reach direction for a given (a) height from the floor...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding No Weight - Side Approach Scooter
reaching abilities of scooter users represented as the percentage of users expected to reach to a target location in the lateral or sideways reach direction for a given (a) height from the floor...
-
Examples of access:
Exam table that lowers to 17-19 inches from the floor Many people find these tables easier to use. There are many ways to help people get access....
-
11B-603.5 Accessories
All operable parts, including coin slots, shall be 40 inches (1016 mm) maximum above the finish floor....
-
11B-904.4 Sales and service counters
number of existing mail boxes, the counter shall be permitted to have a portion which is 24 inches (610 mm) long minimum complying with Section 11B-904.4.1 provided that the required clear floor...
-
11B-603.5 Accessories
All operable parts, including coin slots, shall be 40 inches (1016 mm) maximum above the finish floor....
-
11B-904.4 Sales and service counters
number of existing mail boxes, the counter shall be permitted to have a portion which is 24 inches (610 mm) long minimum complying with Section 11B-904.4.1 provided that the required clear floor...