Pass through kitchens shall have two entries....
Search Results "Unassisted Entry"
Commonly Searched Documents
-
11B-804.2.1 Pass through kitchen
-
Alternative Designs
The tub has a non-institutional appearance, a fold-down seat, and a swinging side entry door with a pressurized seal for ease of access....
-
1132A.4 Level floor or landing
Primary entry doors, required exit doors or secondary exterior doors with changes in height between the interior surface or floor level and the exterior surface or floor level shall comply...
- SciFit Inclusive Fitness ISO7000R - Recumbent Bike
- Turnstile Security Systems Inc. 6000 GB 2 Optical Turnstile Demonstration Video
-
16. Modification to be completed within six months
Modifications to be completed within six months: As agreed between the parties, within six months of the date of entry of this Consent Decree, Defendants shall make the following physical...
-
G. Door Hardware
Is the door hardware (levers, pulls, panic bars, etc.) on all entry doors to accessible guestrooms and other passage doors within the room usable with one hand, without tight grasping, pinching...
-
H. Door Maneuvering Clearance
.: entry door, connecting room door, bathroom doors and other passage doors) in every accessible guestroom/suite, are there at least 18" of clear floor space on the latch side for persons...
-
Site Constraints
An example might include construction of a new infill building with a historic facade which must be maintained (thus predetermining the entry floor level) and where space for a ramp is not...
-
4.13.6 Maneuvering Clearances at Doors
EXCEPTION: Entry doors to acute care hospital bedrooms for in-patients shall be exempted from the requirement for space at the latch side of the door (see dimension “x” in Fig. 25) if the...
-
11B-608.2.3 Alternate roll-in type shower compartments
A 36 inch (914 mm) wide minimum entry shall be provided at one end of the long side of the compartment....
-
§ 382.40a Boarding assistance for large aircraft
operations with aircraft having a seating capacity of 31 or more passengers at airports with 10,000 or more annual enplanements, in any situation where passengers are not boarded by level-entry...
-
11B-407.2.3.1 Floor designation
A raised star, placed to the left of the floor designation, shall be provided on both jambs at the main entry level. ...
-
11B-608.2.1 Transfer type shower compartments
shower compartments shall be 36 inches (914 mm) by 36 inches (914 mm) clear inside dimensions measured at the center points of opposing sides and shall have a 36 inch (914 mm) wide minimum entry...
-
407.2.3.1 Floor Designation
A tactile star shall be provided on both jambs at the main entry level. Figure 407.2.3.1 Floor Designations on Jambs of Elevator Hoistway Entrances...
-
804.2.1 Pass Through Kitchen
Pass through kitchens shall have two entries. Figure 804.2.1 Pass Through Kitchens...
-
11B-608.2.3 Alternate roll-in type shower compartments
A 36 inch (914 mm) wide minimum entry shall be provided at one end of the long side of the compartment....
-
M305.3.1.2 Diagnostic Equipment Containing a Wheelchair Space
On diagnostic equipment containing wheelchair spaces with one entry that also serves as the exit, the length of the gripping surface of horizontal standing supports shall be equal to or...
-
608.3.3 Alternate Roll-In Type Shower Compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
-
E. GRIEVANCE PROCEDURE
Within three (3) months of the entry of this Consent Decree, the County will adopt the attached ADA Grievance Procedure, Attachment C, distribute it to all of its agencies, post it...
-
Door Closers [4.13.10]
Because it may be difficult for a person with a disability to open a door against the resistance offered by a closer, it is important that the closing action be slow enough to allow entry...
-
Press Boxes [§206.2.7]
field or assembly area is no more than 500 sq. ft. if press boxes are either: free-standing and elevated above grade at least 12’ or located in bleachers with points of entry...
-
1132A.4.1 Thresholds
Thresholds at the primary entry and required exit doors shall be no higher than ½ inch (12.7 mm)....
-
§ 38.125(a)(1) General
All intercity rail cars, other than level entry cars, required to be accessible by §§38.111 (a) and (e) of this subpart shall provide a level-change mechanism or boarding device (e.g., lift...