5.3.2.1 Transfer Sides Recommendation for Stretchers On stretchers, the transfer surface is oriented along the long dimension of the surface on which patients are in the supine, prone...
Search Results "Transfer Shower"
Commonly Searched Documents
-
5.3.2.1 Transfer Sides Recommendation for Stretchers
-
4.21.5 Controls
4.21.5 Controls. None of the respondents indicated that there were any variations from ADAAG regarding the controls.
- Collapsible Water Retainer Shower Dam for Shower Threshold
-
(3) Adjustability: Transfer Surface Intermediate Heights
In the MDE NPRM there was no requirement for the transfer surface to have intermediate transfer heights....
- Proline Drain: Quick Drain USA - Barrier-Free Tub to Shower Conversion
-
M301.2.1, M302.2.1 Transfer Height
M301.2.1, M302.2.1 Transfer Height Proposed requirement: The height of the transfer surface during patient transfer shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum...
-
Ticket transfer. (Section-by-Section Analysis)
Ticket transfer. The Department received many comments asking whether accessible seating has the same transfer rights as general seats....
-
15(d)
the timeframe set forth in subparagraph 15(a), HWI shall ensure that each Post-1993 Owned Hotel and Post-1993 Joint Venture Hotel has the required number of accessible rooms with roll-in showers...
-
Wheelchair Operation (Helping #6)
Requires the Registered User plan or above. Login!
-
11B-809.10.6.2 Slope
The slope of the shower floor shall be 1/2 inch (12.7 mm) per foot maximum in any direction and shall slope to a drain....
-
Spacing: ADA Standard Section 609.3
Section 609.3 covers the current ADA Standards for the grab bar spacing between the wall, objects above, below and at the ends of the grab bar.
-
11B-610.3.1 Rectangular seats
FIGURE 11B-610.3.1 RECTANGULAR SHOWER SEAT...
-
610.3.1 Rectangular Seats
Figure 610.3.1 Rectangular Shower Seat...
-
5.4.2.1 Transfer Support Length for Stretchers
5.4.2.1 Transfer Support Length for Stretchers. Transfer supports on stretchers should be a minimum of 15 inches long....
-
11B-1002.5.2 Transfer height
The height of amusement ride seats designed for transfer shall be 14 inches (356 mm) minimum and 24 inches (610 mm) maximum measured from the surface of the load and unload area....
-
11B-1002.5.2 Transfer height
The height of amusement ride seats designed for transfer shall be 14 inches (356 mm) minimum and 24 inches (610 mm) maximum measured from the surface of the load and unload area....
-
11B-1002.5.2 Transfer height
The height of amusement ride seats designed for transfer shall be 14 inches (356 mm) minimum and 24 inches (610 mm) maximum measured from the surface of the load and unload area....
-
Soft Contained Play Structures: ADA Standard Section 1008.2.2
EXCEPTION: Transfer systems complying with 1008.3 shall be permitted to be used as part of an accessible route....
-
610.3.1 Rectangular Seats
Figure 610.3.1 Rectangular Shower Seat...
-
1002.5 Amusement Ride Seats Designed for Transfer
Advisory 1002.5 Amusement Ride Seats Designed for Transfer....
-
1002.5 Amusement Ride Seats Designed for Transfer
Amusement ride seats designed for transfer shall comply with 1002.5 when positioned for loading and unloading. Advisory 1002.5 Amusement Ride Seats Designed for Transfer....
-
1002.5 Amusement Ride Seats Designed for Transfer
Amusement ride seats designed for transfer shall comply with 1002.5 when positioned for loading and unloading. Advisory 1002.5 Amusement Ride Seats Designed for Transfer....
-
Best Practices in the Design of Toileting and Bathing Facilities for Assisted Transfers
Best Practices in the Design of Toileting and Bathing Facilities for Assisted Transfers Final Report August 1, 2001 Jon A....
-
Additional Transfer Techniques: Use of Stretchers and Gurneys
Once the stretcher is positioned next to the equipment and set at the right height, many people will require assisted transfers utilizing devices such as transfer boards or slip sheets to...