Surfaces of transfer walls shall not be sharp and shall have rounded edges....
Search Results "Transfer Shower"
Commonly Searched Documents
-
11B-1009.4.4 Surface
-
M301.2.3 Transfer Sides
The transfer surface shall be located to provide options to transfer from a mobility device onto one short side (depth) and one long side (width) of the surface....
-
1009.4.4 Surface
Surfaces of transfer walls shall not be sharp and shall have rounded edges....
-
1009.5.5 Surface
The surface of the transfer system shall not be sharp and shall have rounded edges....
-
Surface
Surface The surface of the transfer platform and steps must not be sharp and must have rounded edges to prevent injuries....
-
Platform Height
Platform Height Transfer platforms must be between 16 and 19 inches high, measured from the deck....
-
Height
Height The transfer wall height must be 16 inches minimum to 19 inches maximum, measured from the deck....
-
4.1.2 Surface Design of Examination Tables and Chairs
Thus, contouring must be addressed in considering minimum height standards for accessibility of transfer surfaces (Section 5.1.4)....
-
1009.4.2 Height
The height of the transfer wall shall be 16 inches (405 mm) minimum and 19 inches (485 mm) maximum measured from the deck....
-
11B-1009.4.2 Height
The height of the transfer wall shall be 16 inches (406 mm) minimum and 19 inches (483 mm) maximum measured from the deck....
-
11B-1009.4.2 Height
The height of the transfer wall shall be 16 inches (406 mm) minimum and 19 inches (483 mm) maximum measured from the deck....
-
5.4.4.1 Transfer Support Distance from Transfer Surface Recommendation for Stretchers
5.4.4.1 Transfer Support Distance from Transfer Surface Recommendation for Stretchers The Committee recommends locating the transfer support along the long side of the of the transfer...
-
11B-224.2 Guest rooms with mobility features
Provide either a bathtub complying with Section 11B-607 or a transfer type shower complying with Section 11B-608.2.1. 2. ...
-
Surface
Surface Since people using transfer walls are in bathing suits, their skin may be in contact with the wall....
-
Clear Deck Space: ADA Standard Section 1009.4.1
A clear deck space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
11B-1009.4.1 Clear deck space
A clear deck space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (355 mm) minimum and 17 inches (430 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum. ...
-
11B-1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (356 mm) minimum and 17 inches (432 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum....
-
11B-1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (356 mm) minimum and 17 inches (432 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum....
-
11B-1002.6 Transfer devices for use with amusement rides
When using a transfer device to access an amusement ride, the least number of transfers and the shortest distance is most usable....
-
11B-1002.6 Transfer devices for use with amusement rides
When using a transfer device to access an amusement ride, the least number of transfers and the shortest distance is most usable....
-
11B-1002.6 Transfer devices for use with amusement rides
Transfer devices for use with amusement rides should permit individuals to make independent transfers to and from their wheelchairs or mobility devices....
-
Verify Rough Plumbing
from side walls. 11B-606.6 Location of bathtub controls and drain. 11B-607.5 Installation height and location of shower...
-
Verify Rough Plumbing
from side walls. 11B-606.6 Location of bathtub controls and drain. 11B-607.5 Installation height and location of shower...