Any opinions, findings, conclusions or recommendations expressed in this publication are those of the authors and do not necessarily reflect the views or policies of the Access Board....
Search Results "Recommend"
-
Accessible Exterior Surfaces Technical Article
-
3.3.15.3 Side (lateral) reach – over an obstruction depth of 610 mm
The results suggest that the recommended maximum depth of 610 mm (24 in.) obstruction would need to be reduced significantly in order to accommodate a majority of our study’s WhMD users....
-
Head and Back Support (M301.3.3 and M302.3.3)
This is consistent with ANSI/AAMI HE75 which recommends that the “support surface needs to be adjustable or have adjustable support features (e.g., for the head, neck, back, lumbar region...
-
M102.1 Defined Terms
Comments should identify specific terms in the proposed standards that should be defined and, where possible, recommend definitions....
-
11B-505.4 Height
A maximum height of 28 inches (710 mm) measured to the top of the gripping surface from the ramp surface or stair nosing is recommended for handrails designed for children....
-
6. Classroom Acoustics
Consistent with long-standing recommendations for good practice in educational settings, the standard set specific criteria for maximum background noise (35 decibels) and reverberation time...
-
11B-505.4 Height
A maximum height of 28 inches (710 mm) measured to the top of the gripping surface from the ramp surface or stair nosing is recommended for handrails designed for children....
-
6. Classroom Acoustics
Consistent with long-standing recommendations for good practice in educational settings, the standard set specific criteria for maximum background noise (35 decibels) and reverberation time...
-
6. Classroom Acoustics
Consistent with long-standing recommendations for good practice in educational settings, the standard set specific criteria for maximum background noise (35 decibels) and reverberation time...
-
505.4 Height
A maximum height of 28 inches (710 mm) measured to the top of the gripping surface from the ramp surface or stair nosing is recommended for handrails designed for children....
-
Section 1193.51 Compatibility [1193.41 in the NPRM] (Section-by-Section Analysis)
Trace recommended that the requirement for a physical connection point be removed. Response....
-
Other International Law Issues
in a variety of areas, and Annex 9 includes a series of standards and recommendations concerning transportation of persons with disabilities....
-
Toilet and Bathing Rooms
Commenters recommended that section 213, Toilet Facilities and Bathing Facilities, of the 2010 Standards include requirements that unisex toilet and bathing rooms be provided in certain...
-
1. Transfer Supports
The Access Board received 31 comments to these questions and the MDE Advisory Committee made 10 recommendations regarding the transfer support section....
-
B. Scoping Requirements for Units with Communication Features
The ADA and ABA Accessibility Guidelines require at least 2 percent of the residential dwelling units in a facility to provide communication features.35 The advisory committee did not recommend...
-
General [4.5.1]
(Recommended levels in the ADAAG appendix of 0.6 for level surfaces and 0.8 for ramps are advisory, not mandatory)....
-
Station 3-Turning Radii
For bicycles, AASHTO (p. 38) recommends a minimum radius of 12 m (36 ft) for a design speed of 20 km/h (12 mi/h), increasing to a minimum radius of 74 m (225 ft) for a design speed of 50...
-
Opening Force [§404.2.9]
Recommendation: Automation of exterior doors is recommended, especially where the opening force is likely to be significant. ...
-
11B-242.2 Swimming pools
Where more than one means of access is provided into the water, it is recommended that the means be different....
- Lake Ledge Naturalist Discovery Pen
-
M301.4.1 Clearance in Base (Section-by-Section Analysis)
This commenter asserted that the proposed six-inch vertical clearance would require redesign of every medical bed and stretcher on the market, and recommended reducing the required clearance...
-
Rulemaking History
The Access Board established a federal advisory committee in 1999 to recommend accessibility guidelines for pedestrian facilities in the public right-of-way....
-
A. Scoping Requirements for Units with Mobility Features
Mobility Features The ADA and ABA Accessibility Guidelines require at least 5 percent of the residential dwelling units in a facility to provide mobility features.25 The advisory committee recommended...
-
Introduction
In 1993, the Access Board established an advisory committee of 27 members to recommend accessibility guidelines for recreation facilities....