11B-247.1.2.1 Platform edges
Platform boarding edges shall have detectable warnings complying with Sections 11B-705.1.1 and 11B-705.1.2.1.
-
11B-705.1.2.1 Platform edges
Detectable warning surfaces at platform boarding edges shall be 24 inches (610 mm) wide and shall extend the full length of the public use areas of the platform.
-
11B-810.6.1 Entrances
Where signs identify a station or its entrance, at least one sign at each entrance shall comply with Section 11B-703.2 _|Signs; Raised Characters|_ and shall be placed in uniform...
-
705.2 Platform Edges
Detectable warning surfaces at platform boarding edges shall be 24 inches (610 mm) wide and shall extend the full length of the public use areas of the platform.
-
810.6.1 Entrances
Where signs identify a station or its entrance, at least one sign at each entrance shall comply with 703.2 and shall be placed in uniform locations to the maximum extent practicable....
-
T703 International Symbol of Accessibility
[See subsections ...]
-
T209 Fare Collection Devices
[See subsections ...]
-
T213 Seats
[See subsections ...]
-
16. In § 38.111
§ 38.111 [Amended] 16. In § 38.111,
-
10.3.1(12)(a)
(a) If an interior public pay telephone is provided in a transit facility (as defined by the Department of Transportation) at least one interior public text telephone shall be...
-
10.3.1(17)
(17) Where provided, elevators shall be glazed or have transparent panels to allow an unobstructed view both in to and out of the car. Elevators shall comply with 4.10. EXCEPTION:...
-
10.3.3(1)
(1) For the purpose of complying with 4.1.6(2) Alterations to an Area Containing a Primary Function, an area of primary function shall be as defined by applicable provisions of 49...
-
Additional Technical Criteria Considered for Handrails on Ramps
M303.3.3.5 would require handrails to be provided on each side of the ramp when the vertical rise of the ramp exceeds 6 inches. This is consistent with the 2004 ADA and ABA...
-
§ 38.125(c)(6) Attachment
(6) Attachment—
-
11B-705.1.2.1 Platform edges
11B-705.1.2.1 Platform edges. Detectable warning surfaces at platform boarding edges shall be 24 inches (610 mm) wide and shall extend the full length of the public use areas of the...
-
§ 38.105 Priority seating signs
[See subsections ...]
-
11B-247.1.2.1 Platform edges
Platform boarding edges shall have detectable warnings complying with Sections 11B-705.1.1 and 11B-705.1.2.1.
-
§ 38.117 Floors, steps and thresholds
[See subsections ...]
-
§ 38.127(b)
(b) Each accessible compartment shall contain a restroom complying with §38.123(a) which can be entered directly from such compartment.
-
§ 38.125(b)(2)(i) Requirements
(i) Requirements. The controls shall be interlocked with the car brakes, propulsion system, or door, or shall provide other appropriate mechanisms or systems, to ensure that the car...
-
§ 38.83(b)(7) Platform gaps
(7) Platform gaps. Any openings between the lift platform surface and the raised barriers shall not exceed 5/8 inch wide. When the lift is at vehicle floor height with the inner...
-
§ 38.105(a)