The tops of tables and counters shall be 26 inches (660 mm) minimum and 30 inches (760 mm) maximum above the finish floor or ground.
Search Results "Handrail Height"
-
902.4.2 Height
-
902.4.2 Height
The tops of tables and counters shall be 26 inches (660 mm) minimum and 30 inches (760 mm) maximum above the finish floor or ground.
-
Height – M301.2.1 & M302.2.1
Height – M301.2.1 & M302.2.1 The subcommittee discussed the increments for adjustability and decided that infinite adjustability is the appropriate standard as both electronic and...
-
11B-605.2 Height and depth
Urinals shall be the stall-type or the wall-hung type with the rim 17 inches (432 mm) maximum above the finish floor or ground. Urinals shall be 13½ inches (343 mm) deep minimum...
-
Raised Characters
Specifications for raised characters in section 703.2 address the depth, case, style or font type, character proportion and height, stroke thickness, and character and line spacing....
-
11B-703.5.5 Character height
Minimum character height shall comply with Table 11B-703.5.5....
-
11B-703.5.5 Character height
Minimum character height shall comply with Table 11B-703.5.5....
-
11B-703.4.1 Height above finish floor or ground
[2010 ADA Standards] 703.4.1 Height Above Finish Floor or Ground....
-
11B-703.4.1 Height above finish floor or ground
[2010 ADA Standards] 703.4.1 Height Above Finish Floor or Ground....
-
Transfer Protocols
Summary description and experimental setup for the five protocols (A-E) Protocol A: Adjustable Height Level height, maximum height transfer and minimum height...
-
Aisle Ramps in Assembly Areas
In assembly areas, aisle ramps required to be accessible are exempt from some handrail requirements....
-
Dune Crossings [1018.10]
A dune crossing that is part of a beach access route and has a slope that exceeds 1:20 (5 percent) must also provide handrails that comply with section 505 of the ABA Standards and must...
-
11B-411.2.1.2.4.2 Size
Elevator assignment characters shall be 1 inch high (25 mm) minimum.
-
11B-411.2.1.2.4.2 Size
Elevator assignment characters shall be 1 inch high (25 mm) minimum.
-
a. Transfer Surface Adjustability
The Board considered it likely that diagnostic equipment would be adjustable in height to serve practitioners’ needs however, the transfer surface could be fixed within the proposed height...
-
Railings—Guardrails, Handrails, and Safety
For safety, the International Building Code (IBC), http://www.iccsafe.org, section 1003.2.12 contains requirements for guardrail height and the spacing of rails where there is a drop off...
- Figure 904.3.2 Check-Out Aisle Counters – Drawing from the U.S. Access Board
-
Changes in Level and Horizontal Gaps
This height allows for freight passage while reducing the height of the first step of a rail car above the platform....
-
A4.32.4 Height of Tables or Counters
A4.32.4 Height of Tables or Counters. Different types of work require different table or counter heights for comfort and optimal performance....
-
11B-604.4 Seats
The seat height of a water closet above the finish floor shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum measured to the top of the seat....
-
11B-604.4 Seats
The seat height of a water closet above the finish floor shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum measured to the top of the seat....
-
Line Spacing: ADA Standard Section 703.2.8
Spacing between the baselines of separate lines of raised characters within a message shall be 135 percent minimum and 170 percent maximum of the raised character height....
-
11B-703.2.8 Line spacing
Spacing between the baselines of separate lines of raised characters within a message shall be 135 percent minimum and 170 percent maximum of the raised character height....