Clear floor or ground space shall be positioned adjacent to the dishwasher door....
Search Results "Floor Slope"
-
11B-804.6.3 Dishwasher
-
11B-804.6.3 Dishwasher
Clear floor or ground space shall be positioned adjacent to the dishwasher door....
-
11B-703.5.6 Height from finish floor or ground
Visual characters shall be 40 inches (1016 mm) minimum above the finish floor or ground....
-
11B-703.5.6 Height from finish floor or ground
Visual characters shall be 40 inches (1016 mm) minimum above the finish floor or ground....
-
410.3 Clear Floor Space
410.3 Clear Floor Space. Clear floor space in platform lifts shall comply with 305....
-
1134A.6, Item 2
Slope. The maximum slope of the shower floor shall be ½ inch (12.7 mm) per foot in any direction and shall slope to a drain....
-
1134A.6, Item 2
Slope. The maximum slope of the shower floor shall be ½ inch (12.7 mm) per foot in any direction and shall slope to a drain....
-
Surface and Slope [1015.5 and 1015.6]
When the surface of clear ground spaces and turning spaces is constructed of asphalt, concrete, or boards, the slope of the surface must be no steeper than 1:48 (2 percent) in any direction...
-
3 [§ 4.3.7]
3 [§ 4.3.7] The cross slope of the curb ramp is perpendicular to the running slope. Unlike the running slope, which runs along the ramp, the cross slope is measured across the ramp....
-
Knee and Toe Clearance: ADA Standard Section 305.4
Section 305.4 covers the current ADA Standards for knee and toe clearance included in clear floor space.
-
A. Slope at Door
A. If a fully automatic door is not provided, is the walkway in front of the lobby door level, without any portion steeper than 1:50 (critical dimension of ´" or less), so persons...
-
Carpet: ADA Standard Section 302.2
Section 302.2 covers the current ADA Standards for carpet.
-
Ramps M303:3.3, 3.3.1, 3.3.2
Ramp runs would be required to have a running slope not steeper than 1:12 and a cross slope not steeper than 1:48....
-
302.1 Floor or Ground Surfaces
302.1 Floor or Ground Surfaces Both section 4.5.1 of the 1991 Standards and section 302.2 of the 2010 Standards require that floor or ground surfaces along accessible routes and in accessible...
-
11B-903.2 Clear floor or ground space
Clear floor or ground space complying with Section 11B-305 shall be provided and shall be positioned at the end of the bench seat and parallel to the short axis of the bench....
-
11B-903.2 Clear floor or ground space
Clear floor or ground space complying with Section 11B-305 shall be provided and shall be positioned at the end of the bench seat and parallel to the short axis of the bench....
-
11B-903.2 Clear floor or ground space
Clear floor or ground space complying with Section 11B-305 shall be provided and shall be positioned at the end of the bench seat and parallel to the short axis of the bench....
-
Submerged Depth
This depth is necessary for individuals using the sloped entry to become buoyant....
-
1009.3.3 Handrails
At least two handrails complying with 505 shall be provided on the sloped entry....
-
11B-1002.4.1 Floor or ground surface
The floor or ground surface of wheelchair spaces shall be stable and firm....
-
11B-1002.4.1 Floor or ground surface
The floor or ground surface of wheelchair spaces shall be stable and firm....
-
Step 2: Identify the Presence of Limiting Factors
Does the combined trail running slope (grade) and cross slope exceed 1:2.5 (40 percent) for a continuous distance of 20 feet (6 meters) or more?...
-
11B-1009.3.3 Handrails
At least two handrails complying with Section 11B-505 shall be provided on the sloped entry....
-
M303.3.3.1 Running Slope
Ramp runs shall have a running slope not steeper than 1:12....