Clearances around water closets and in toilet compartments shall comply with 604.3....
Search Results "Water Closet Clear Floor Space"
-
604.3 Clearance
-
11B-604.3 Clearance
Clearances around water closets and in toilet compartments shall comply with Section 11B-604.3....
-
11B-604.3 Clearance
Clearances around water closets and in toilet compartments shall comply with Section 11B-604.3....
-
4.16.2 Clear Floor Space
4.16.2 Clear Floor Space. In order to accommodate independent wheelchair use, guidelines for clear floor space in ADAAG vary according to path of approach to the toilet....
-
11B-604.3 Clearance
Clearances around water closets and in toilet compartments shall comply with Section 11B-604.3....
-
604.3.1 Size
Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular from the rear wall....
-
604.3.1 Size
Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular from the rear wall....
-
11B-604.3.2 Overlap
The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible...
-
11B-604.3.2 Overlap
The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible...
- Figure 604.3.1 Size of Clearance at Water Closets – Drawing from the U.S. Access Board
- Mockett TBR1-SSS Wall Mounted Toilet Brush Holder
- Mockett TBR8 Fixed Toilet Brush
-
Clear Floor Space: ADA Standard Section 808.3
Each jury box and witness stand shall have, within its defined area, clear floor space complying with 305....
-
J. Transfer Space
J. If there is a lavatory in the accessible stall, is there 42" between the center of the toilet and the near edge of the adjacent lavatory to permit persons with disabilities to...
-
Clear Floor or Ground Space: ADA Standard Section 1002.6.1
A clear floor or ground space complying with 305 shall be provided in the load and unload area adjacent to the transfer device....
-
Approach: ADA Standard Section 305.6
Section 305.6 covers the current ADA Standards for the approach to clear floor space.
-
Size: ADA Standard Section 305.3
Section 305.3 covers the current ADA Standards for the required size of compliant clear floor or ground space.
-
General: ADA Standard Section 305.1
Section 305.1 of the ADA Standards covers information in the current ADA Standards for clear floor or ground space.
-
11B-309.2 Clear floor space
A clear floor or ground space complying with Section 11B-305 shall be provided....
-
11B-309.2 Clear floor space
A clear floor or ground space complying with Section 11B-305 shall be provided....
-
11B-213.3.2 Water closets
Where water closets are provided, at least 5 percent but no fewer tan one shall comply with Section 11B-604. [2010 ADA Standards] 213.3.2 Water Closets....
-
11B-213.3.2 Water closets
Where water closets are provided, at least 5 percent but no fewer tan one shall comply with Section 11B-604. [2010 ADA Standards] 213.3.2 Water Closets....
-
Clear Floor Space: ADA Standard Section 606.2
Section 606.2 covers the current ADA Standards for clear floor space at lavatories and sinks.
-
4.34.5.7 CLEAR FLOOR SPACE
Clear floor space at fixtures may overlap....